Amtech
6-110
6
In-built PLC Block
PSI
PSO
Analog I/P
& O/P
Monitor
Parameter
In-Built PLC
Function
Main Control (Inverter)
In-Built PLC
Fig. 6-2 Block Diagram of In-built PLC function with Main Control
Fig. 6-2 is a block diagram of main control and In-built PLC function. All Digital Input and Output,
Analog Input and output are connected with main control.
Now user can program In-built PLC for his application. User can also take output of the drive as PLC
Input and output from PLC to the drive as an Input.
In-built PLC Function Related Parameters and Command.
The In-built PLC function related parameters are listed below.
1.
In-built PLC
(C312)
:
Use this parameter to enable the In-built PLC Function.
2.
In-built PLC Command
(P101 to PC10)
:
Input the PLC commands to be executed with the In-built PLC Function in parameters P101 to
PC10.
3.
PLC Display Parameter
(M313 to M322)
: In-built PLC
Display
For PLC programming, there are 115 numbers of 16-bit register and 100 numbers of 1-bit flag.
10 values of signed 16-bit register can be displayed in parameter M313 to M322 and these values
will be saved in EEPROM at the time of power off. (Related PLC command is DISPLAY_REG
(061)) and during power on these parameters value will come in register 76 to 85, 8 different flag
bit status can be display in parameter M323. (Related PLC command is DISPLAY_FLG (062)).
4.
Digital Input
From Inverter (PSI Status) to In-built PLC:
Parameters C101 to C106 and C114 to C115 have 41 selectable options. In these, 28 to 35 are
for PLC input options. Now to take PSI status as a PLC input, select one of the PLC input option
from these parameters. Use
READ_PSI
(047) command in PLC program for this operation.
5.
Digital Output From In-built PLC to Inverter (PSO Status):
Parameters C107 to C113 have 36 Selectable options. In these, 26 to 32 options are for In-built
PLC output. Now to take In-built PLC’s output as Inverter’s PSO output, select one of the PLC
option from these parameters. Use
WRITE_PSO
(049) command in PLC program for this
operation.
6.
Digital Input From
In-built PLC to Inverter (PSI Status):
Parameters C101 to C106 and C114 to C115 have 41 selectable options.
User can activate one of 1 to 27 options of these parameters, without any extern digital signal on
PSI by using In-built PLC. Use
WRITE_PSI
(048) command in PLC program for this operation.
7.
Digital Output From Inverter (PSO Status) to In-built PLC:
User can read and use status of PSO from inverter for In-built PLC application.
To read the PSO status in In-built PLC, use
READ_PSO
(046) command in PLC program.
Содержание Axpert-Eazy AMT-011-4
Страница 2: ...Amtech ii...
Страница 19: ...Axpert Eazy AC Variable Frequency Drive 2 11 2 400V Series AMT 200 4 AMT 250 4...
Страница 22: ...Amtech 2 14 2 This Page is intentionally left blank...
Страница 37: ...Axpert Eazy AC Variable Frequency Drive 4 9 4...
Страница 38: ...Amtech 4 10 4 This page is intentionally left blank...
Страница 46: ...Amtech 5 8 5 This page is intentionally left blank...
Страница 216: ...Amtech 13 6 13 This page is intentionally left blank...
Страница 221: ...Axpert Eazy AC Variable Frequency Drive A 5 13 A Outline Dimensions...
Страница 239: ...Notes...
Страница 240: ...Notes...
Страница 241: ......
Страница 242: ...AMTECH...