AMETEK CTS
OCS 500 N6 series
Manual for Operation
V 5.24
65 / 80
10.4. Verification Damped Oscillatory Wave
10.4.1. Verification Parameter slow damped oscillatory wave
IEC 61000-4-18
(open circuit)
V peak
±10%
Rise time first peak
75ns
±20%
Oscillating frequency
100, 1000 kHz
±10%
Decaying of peak 5-1 > 50% of peak 1
Decaying of peak 10-1 < 50% of peak 1
(short circuit)
I peak (200
)
1.25, 2.5, 5, 10A
±20%
Impedance
200
±20%
Remark:
The output impedance is calculated result of the ratio of the first peak open circuit voltage and the
first peak short current, measured with a 2500V pulse.
Typical pulses, measured with a calibrated equipment
U set : +2500V 100kHz
U peak
= 2507V
Peak 5
= 1629V (65%)
Peak 10
= - 963V (38%)
tr
= 71.098ns
frequency
= 96.917kHz
U set : +2500V 1000kHz
U peak
= 2514V
Peak 5
= 1748V (69%)
Peak 10
= - 964V (38%)
tr
= 76.4ns
frequency
= 975.65kHz
Burst definition
:
Burst duration : (td + tr)>2s
td :
not specified
Frequency f :
40/s for 100kHz
400/s for 1MHz
Test duraton T :
Phase relationship mains frequency:
no requirement;