Configuration Parameters (Continued)
Probe Length Factory set to probe length as ordered. Edit if probe length
is changed.
On cable sensors, this includes the weight.
Enter probe length from tip of to bottom of probe mounting
in Level or Distance Units
User editable value
Default = 600”
Sensor Type The sensor type was preset at the factory, based on the
order. This function allows you to change sensor type.
Do not change without Factory consultation.
Single Cable
Twin Cable
Single Rod)
Twin Rod
Coax
Main window buttons
Read
Transmitter
Downloads configuration data from the electronic unit to
the computer
Write to
Transmitter
Uploads changes from the computer to the electronic unit
Real Time
View
Opens window to display current level and distance
measurements and status
Tank Mapping
Allows an insitu vessel profile to be obtained by recording
non-level reflections above the actual level. This recorded
profile is subtracted from the live reading to eliminate
fixed reflections from the measurement.
Enter the distance from sensor mounting to a point above
the level to be mapped. Mapping too close to the level will
map out the actual level.
User editable value
Edit “Map to
Distance” from the
sensor mounting.
Recommended “Map
to Distance” is 12”
above the actual
level.
Contact factory if
mapping to a point
less than 8” above
the level.
D/A Trim
Allows a field reference meter to be connected to the
transmitter for adjusting transmitter output current
4 mA Trim:
3.5 to 4.5
20 mA Trim
19.5 to 20.5
Configure
Meter
Configures the 7-Digit Display.
Enabling Toggle will automatically scroll the display
through all enabled options.
Available display options are: Range, Level, Volume,
Distance, Loop Current.
Enable/Diasble
Содержание Impulse GW Series
Страница 4: ...Contents...
Страница 6: ...Section 1...
Страница 16: ...Section 2...
Страница 25: ...Installation 19 2 6 Dual Compartment Housing...
Страница 26: ...Section 3...
Страница 56: ...Section 4...
Страница 82: ...Impulse Series 76 5 2 1 System Dimensions Continued...
Страница 83: ...Supplementary ATEX Installation Instructions 77 5 2 1 System Dimensions Continued...
Страница 84: ...Impulse Series 78 5 2 1 System Dimensions Continued...
Страница 86: ...Section 6...
Страница 92: ...Section 7...
Страница 93: ...Control Drawings 87 Section 7 Control Drawings 7 1 FM FMC Control Drawings...
Страница 94: ...Impulse Series 88 7 1 FM FMC Control Drawings Continued...
Страница 95: ...Control Drawings 89 7 2 ATEX Control Drawings...
Страница 96: ...Impulse Series 90 7 2 ATEX Control Drawings Continued...