2.5.2 Installation on Non Metal Vessels
The Impulse® TDR requires a metal surface at the mounting. When
mounting either a Single Rod or Single Cable probe without Wave Guide
Nozzle Eliminator on a non-metal vessel, use a 2” or greater ANSI metal
flange to act as a “launch plate” directly at the instrument mounting. A
launch plate can be fabricated with an 8” (200 mm) diameter metal disc
that can be threaded in constant contact with the metal NPT mounting
thread placed above a non-metal flange or thread mounting.
Twin element probes (coaxial, twin rod or twin cable) do not require a
launch plate.
2.6
Installation on Non Metal Vessels
The Impulse™ TDR requires a metal surface at the mounting. When mounting
either a Single Rod or Single Cable probe on a non-metal vessel, use either a 2”
or greater metal flange or a metal “launch plate” directly at the instrument
mounting. A launch plate can be fabricated with an 8” (200 mm) diameter metal
disc that can be threaded in constant contact with the metal NPT mounting
thread placed above a non-metal flange or thread mounting.
Twin element probes (coaxial, twin rod or twin cable) do not require a launch
plate.
Launch Plate
Impulse
Impulse
Thread Mount
Flange
Mount
AMETEK Drexelbrook Launch Plate provides an 8” (200 mm) diameter disc in
light gauge aluminum for use in non-metal vessel installations. This accessory
should not be placed in contact with the process material.
Impulse TDR Accessory:
Threaded NPT Launch Plates are available in standard Impulse probe thread
sizes:
8” (200 mm) dia. X ¾” NPT
P/N 285-0001-727
8” (200 mm) dia. X 1” NPT
P/N 285-0001-728
8” (200 mm) dia. X 1-1/2” NPT P/N 285-0001-729
Содержание Impulse GW Series
Страница 4: ...Contents...
Страница 6: ...Section 1...
Страница 16: ...Section 2...
Страница 25: ...Installation 19 2 6 Dual Compartment Housing...
Страница 26: ...Section 3...
Страница 56: ...Section 4...
Страница 82: ...Impulse Series 76 5 2 1 System Dimensions Continued...
Страница 83: ...Supplementary ATEX Installation Instructions 77 5 2 1 System Dimensions Continued...
Страница 84: ...Impulse Series 78 5 2 1 System Dimensions Continued...
Страница 86: ...Section 6...
Страница 92: ...Section 7...
Страница 93: ...Control Drawings 87 Section 7 Control Drawings 7 1 FM FMC Control Drawings...
Страница 94: ...Impulse Series 88 7 1 FM FMC Control Drawings Continued...
Страница 95: ...Control Drawings 89 7 2 ATEX Control Drawings...
Страница 96: ...Impulse Series 90 7 2 ATEX Control Drawings Continued...