![Amazone Pantera 4503 Скачать руководство пользователя страница 98](http://html1.mh-extra.com/html/amazone/pantera-4503/pantera-4503_operating-manual_2919770098.webp)
Fault
98
ISOBUS field sprayer BAG0171.9 11.20
F15057
Note
One-time calibration of the fill level
sensor has not yet been executed
•
Calibrate fill-level sensor or enter offset value for
fill-level curve (contact your AMAZONE dealer)
F15058
Note
The speed of the flushing water
pump is outside the tolerance range
of +/- 10% of the nominal speed for a
duration of 10 s
•
Check the switching distance of the flushing
water pump speed sensor (BEL004) from the
pump drive shaft (3.5 to 4 mm)
•
Check the oil supply from the tractor
F15059
Note
Speed detection of the flushing water
pump has failed
•
Check the flushing water pump speed sensor
(BEL004) connection cable
•
Check the flushing water pump speed sensor
(BEL004)
F15060
Note
The fill level in the flushing water
tank is less than 100 l.
•
Fill the flushing water tank
•
Check the flushing water tank sensor
F15061
Note
One-time calibration of the fill level
sensor has not yet been executed
•
Calibrate the fill level sensor or enter the offset
value for the fill level curve (contact your
AMAZONE dealer)
F15062
Note
Alert of emergency operation func-
tion. Induction bowl position sensor
(BEL092) has failed
---
F15063
Note
Failure of the flushing water tank fill
level sensor (BWA091) or failure of
the valve for filling the flushing water
tank
---
F15064
Note
Voltage value of the boom tilt poten-
tiometer must be within 2.0 V to 3.0
V
•
Recalibrate
•
Ensure that the implement is positioned horizon-
tally
•
Check the tilt sensor and connection cable
F15065
Warning In order to operate the folding func-
tion, the speed must not be greater
than 3 km/h
•
Reduce speed
•
Check the signal of the selected source for the
speed
•
Select a different source for the speed
F15066
Alarm
The basis computer of the sprayer
does not receive any messages from
the yaw rate sensor
•
Check the connection cable and yaw rate sensor
•
Check fuses F1 and F2
•
Check the settings in the Setup menu
F15067
Note
Failure of the spray liquid tank fill
level sensor (BWA090) or failure of
the valve for filling the spray liquid
tank
---
F15068
Warning Spring suspension computer sends a
sensor signal for detecting the front
left spring position that is outside the
permissible signal range of 2 to 22
mA
•
Check the height detection on the axle and
check the connection cable
•
Check the implement settings (sensor only with
UX11200)