Fault
ISOBUS field sprayer BAG0171.9 11.20
97
F15042
Alarm
ISOBUS shortcut button ISB is no
longer activated (with AmaTron 3 =
On / Off switch)
---
F15043
Note
No signal for PTO shaft speed on the
ISOBUS
•
PTO shaft speed must be sent by TECU
•
As an alternative, select another source for the
pump speed in the Implement settings menu
(contact your AMAZONE dealer)
F15044
Warning Right ultrasonic sensor does not
send a signal
•
Check the right ultrasonic sensor, extension
cable, and the connection cable (including ampli-
fication electronics) and replace if necessary
F15045
Warning The voltage of the height potenti-
ometer is outside the permissible
signal range of 2 to 22 mA
•
Check the height potentiometer and connection
cable
F15046
Warning Setpoint for the oil reservoir cannot
be reached
•
Check/switch-on the oil supply
•
Check the signal of the hydro accumulator pres-
sure sensor
F15047
Note
Appears when the job computer
detects that the values taught are not
plausible (e.g., value 5 is less than
value 4, although values 6, 7, and 8
are again greater and values 1, 2, 3
are less) after the teach-in process
for the fill level curve (rear tank and /
or front tank).
•
Check the measuring points of the fill level curve
for plausibility
F15048
Note
The computer must be restarted to
apply the changed settings
•
Activate the ACK button on the ISOBUS termi-
nal, restart the job computer directly, without let-
ting time elapse
F15049
Warning An error has been detected in the
runtime monitoring of job computer
extension unit 1.
•
Restart the implement
•
Check the job computer extension unit 1 connec-
tion cable
•
Check fuse F6
F15050
Warning An error has been detected in the
runtime monitoring of job computer
extension unit 2.
•
Restart the implement
•
Check the job computer extension unit 2 connec-
tion cable
•
Check fuse F6
F15052
Warning Despite activating the spring sus-
pension (by the operator, or automat-
ically by the job computer), no
change in the spring suspension
sensor signal is determined.
•
Check the spring suspension oil supply/valves
•
Check the spring suspension position sensors
•
Check the spring suspension calibration
F15053
Note
One-time calibration of the sensors
on the spring suspension has not yet
been performed
•
Calibrate the spring suspension in the implement
Setup (contact your AMAZONE dealer)
F15054
Note
Possible causes:
•
Induction bowl position sensor
(BEL092) has failed
•
Spray liquid fill level sensor
(BWA090) has failed
•
Communication between the Com-
fort Package Plus job computer
(AEL051) and base computer
(AEL652)
•
Check the sensors
•
Check fuse F1
•
Check fuse F2
•
Check the cable connection
F15055
Note
--
See instructions in the message
F15056
Note
--
See instructions in the message