Field menu
28
ISOBUS field sprayer BAG0171.9 11.20
Filling
The front tank is filled via the field sprayer UF.
•
Before filling the front tank and field sprayer together, adjust the
indicator limit for the fill level.
•
To avoid overfilling of the front tank, the respective valve closes
automatically when the maximum volume is reached.
Internal cleaning
The front tank is equipped with an internal cleaning device that is
operated in parallel with the field sprayer.
→
See the UF operating manual.
During / after internal cleaning:
•
Pumping to the rear
must be switched on until the front
tank is empty.
→
Is executed automatically on machines with Comfort Package!
•
After internal cleaning: Execute complete emptying.
Failure of a fill level sensor
If a fill level sensor fails
•
an alarm signal appears,
•
the system switches from
automatic
mode to
manual
mode,
•
the two Flow Control valves close.