Fault
100
ISOBUS field sprayer BAG0171.9 11.20
F15083
Warning
The voltage on at least one nozzle body is
less than 10 V
•
Check the nozzle body connection
cable
•
Check the voltage supply from the trac-
tor
F15084
Warning
Faulty configuration / addressing of the
nozzle body
•
Check the nozzle body connection
cable
•
Check the voltage supply from the trac-
tor
•
Have nozzle bodies been swapped out?
•
Contact your AMAZONE dealer
F15085
Note
The voltage supply to the AmaSwitch job
computer is less than 8 V
•
Check the AmaSwitch job computer
connection cable
•
Check the voltage supply from the trac-
tor
F15086
Note
There has been an attempt to activate
Section Control automatic mode, but all of
the prerequisites are not met
---
F15087
Note
See instruction
•
Repeat cleaning procedure
F15088
Note
The configuration of the boom width and
working width do not match
•
Check the settings
F15089
Warning
Error on the left boom half, e.g. a short
circuit or overload
•
Check the nozzle body connection
cable
•
Check the voltage supply from the trac-
tor
•
Check the connection lines in the boom
F15090
Warning
Error on the right boom half, e.g. a short
circuit or overload
•
Check the nozzle body connection
cable
•
Check the voltage supply from the trac-
tor
•
Check the connection lines in the boom
F15091
Warning
AmaSwitch job computer (AAEL260) is
not in operating status
•
Disconnect the ISOBUS plug from the
tractor, wait for 20 s and reconnect
•
Contact your AMAZONE dealer
F15092
Note
Emergency operation function. The induc-
tion bowl is working at maximum suction
capacity.
---
F15093
Warning
The voltage supply on the ISOBUS load
contacts on the base computer is less
than 10 V
•
Check the fuse on the tractor
•
Check the voltage supply from the trac-
tor
•
Check the ISOBUS connection cable
and base computer connection cable
F15094
Warning
An update has been installed on the
AmaSelect job computer or a new Ama-
Select job computer has been installed on
the implement, and an error has occurred
with the software adjustment
•
Restart the implement and let the trac-
tor run
•
Do not interrupt the voltage supply of
the implement!
F15095
Note
Emergency operation function. The agita-
tor is no longer regulated, but rather is
working at full capacity. The agitator is
closed when the fill level in the main tank
is less than 5%.
---