![Amazone Pantera 4503 Скачать руководство пользователя страница 102](http://html1.mh-extra.com/html/amazone/pantera-4503/pantera-4503_operating-manual_2919770102.webp)
Fault
102
ISOBUS field sprayer BAG0171.9 11.20
F15108
Warning
Position detection signal for the center
boom B on the left is outside the permis-
sible signal range of 2 to 22 mA
•
Check the sensor and sensor connec-
tion
•
Check the sensor connection line
•
Check fuse F2
•
Check fuse F6
F15109
Warning
Position detection signal for the outer
boom on the left is outside the permissible
signal range of 2 to 22 mA
•
Check the sensor and sensor connec-
tion
•
Check the sensor connection line
•
Check fuse F2
•
Check fuse F6
F15110
Warning
Position detection signal for the center
boom A on the left is outside the permis-
sible signal range of 2 to 22 mA
•
Check the sensor and sensor connec-
tion
•
Check the sensor connection line
•
Check fuse F2
•
Check fuse F6
F15111
Warning
Position detection signal for the center
boom B on the right is outside the permis-
sible signal range of 2 to 22 mA
•
Check the sensor and sensor connec-
tion
•
Check the sensor connection line
•
Check fuse F2
•
Check fuse F6
F15112
Warning
Excessive current consumption / or no
current consumption during activation has
been detected on the "Flushing water
pump suction tap" valve.
•
Check the valve connection line
•
Check the valve in the liquid path for
foreign objects
F15113
Warning
Excessive current consumption / or no
current consumption during activation has
been detected on the "Injector" valve.
•
Check the valve connection line
•
Check the valve in the liquid path for
foreign objects
F15114
Warning
Undervoltage, motor temperature is too
high or valve sluggishness has been
detected
•
Check the valve for blockage/foreign
objects
•
Check the valve for sluggishness
•
Contact your AMAZONE dealer
F15115
Warning
Excessive current consumption / or no
current consumption during activation has
been detected on the "drain tap" valve.
•
Check the valve connection line
•
Check the valve in the liquid path for
foreign objects
F15116
Warning
Excessive current consumption / or no
current consumption during activation has
been detected on the "quick emptying"
valve.
•
Check the valve connection line
•
Check the valve in the liquid path for
foreign objects
F15117
Warning
Excessive current consumption / or no
current consumption during activation has
been detected on the "flushing water tank
filling" valve.
•
Check the valve connection line
•
Check the valve in the liquid path for
foreign objects
F15118
Warning
Excessive current consumption / or no
current consumption during activation has
been detected on the "spray liquid tank
pressure filling" valve.
•
Check the valve connection line
•
Check the valve in the liquid path for
foreign objects
F15119
Warning
Excessive current consumption / or no
current consumption during activation has
been detected on the "flushing water tank
pressure filling" valve.
•
Check the valve connection line
•
Check the valve in the liquid path for
foreign objects
Содержание Pantera 4503
Страница 81: ...Settings ISOBUS field sprayer BAG0171 9 11 20 81 Spray table for selecting the nozzles and pressure ranges...
Страница 119: ...ISOBUS field sprayer BAG0171 9 11 20 119...
Страница 120: ......