Field menu
ISOBUS field sprayer BAG0171.9 11.20
25
Automatic or manual nozzle selection
Depending on the selection, the nozzles are
switched either automatically or manually.
Automatic nozzle selection
Automatic nozzle selection is displayed with an A
in the AmaSelect symbol.
When the spray pressure is exceeded or not
reached, the automatic nozzle selection switches
to another nozzle or nozzle selection that is pre-
ferred for the current spray pressure.
Every nozzle/nozzle selection must be config-
ured in advance.
Manual nozzle selection
With manual nozzle selection, the nozzle selec-
tion can be changed by pressing the keys.
Manually selecting nozzles
Each time the button is activated, the nozzle
selection changes in accordance with the positi-
ons selected in the profile.
Cleaning the AmaSelect nozzle bodies
•
Intensive cleaning:
All nozzles of the nozzle body are automat-
ically flushed.
•
Flush boom:
All nozzles of the nozzle body are automatically
flushed.
•
Quick cleaning:
Flush all nozzles of the nozzle body
manually for at least 5 seconds.
•
Boundary nozzles and extra nozzles:
,
When
cleaning the spraying nozzles, flush for at least 5 seconds on
both sides.