![Amazone Pantera 4503 Скачать руководство пользователя страница 96](http://html1.mh-extra.com/html/amazone/pantera-4503/pantera-4503_operating-manual_2919770096.webp)
Fault
96
ISOBUS field sprayer BAG0171.9 11.20
F15025
Warning Front tank computer reports that the
fill level sensor has failed (voltage
value at the potentiometer is outside
the permissible signal range of 2 to
22 mA)
•
Check the potentiometer and connection cable of
the fill level sensor
•
Liquid in the front tank can be pumped by press-
ing and holding the respective direction button
F15026
Warning An error has been detected in the
runtime monitoring of the TwinTer-
minal.
•
Restart the implement
•
Check the TwinTerminal connection cable
•
Check fuse F7
F15027
Warning The voltage of the tilt sensor is out-
side the permissible signal range of 2
to 22 mA
•
Check the tilt sensor and connection cable
•
Check the implement and boom settings in Setup
F15028
Warning The relay does not respond to the
switch commands of the base com-
puter
•
Check relay K1
•
If necessary, replace with an adjacent relay
F15029
Warning The relay does not respond to the
switch commands of the base com-
puter
•
Check relay K2
•
If necessary, replace with an adjacent relay
F15030
Warning The relay does not respond to the
switch commands of the base com-
puter
•
Check relay K3
•
If necessary, replace with an adjacent relay
F15031
Warning Despite activation of the tilt (by the
operator, or automatically by the job
computer), no change in the tilt sen-
sor signal is determined.
•
Check the oil supply
•
Check the tilt adjustment and angle detection.
F15032
Warning An error was detected while monitor-
ing the job computer for additional
part-width sections and edge noz-
zles.
•
Restart the implement
•
Check the connection cable of the job computer
for additional part-width sections
•
Check the tractor fuse
F15033
Warning The voltage of the tilt sensor is out-
side the permissible signal range of 2
to 22 mA
•
Check the tilt sensor and connection cable
•
Check the implement and boom settings in Setup
F15034
Warning The voltage of the "Spring package
for implement" potentiometer is out-
side the permissible signal range of 2
to 22 mA
•
Check the potentiometer and connection cable
•
Check the implement and boom settings in Setup
F15035
Note
Excessive forward speed when driv-
ing in curves, abrupt changing of the
curve direction or inconsistent driving
style when driving in curves
•
Reduce the forward speed
•
Drive in curves with a constant speed and with-
out changing directions
F15036
Warning The tilt adjustment is not calibrated in
the Implement menu.
•
Calibrate tilt adjustment
F15037
Note
Message appears when accessing
the Diagnostics menu
---
F15038
Warning The voltage of the "Boom tilt" poten-
tiometer is outside the permissible
signal range of 0.5 to 4.5 V
•
Check the potentiometer and connection cable
•
Check for correct implement and boom settings
in the Setup
F15039
Warning Left ultrasonic sensor does not send
a signal
•
Check the left ultrasonic sensor, extension cable,
and the connection cable (including amplification
electronics) and replace if necessary
F15040
Note
Source for the forward speed does
not send a signal
•
Select another speed source in the Implement
settings menu
•
Check the settings of the TECU
F15041
Alarm
ISOBUS shortcut button ISB is
pressed (with AmaTron3 = On / Off
switch)
•
Release ISB