Fault
94
ISOBUS field sprayer BAG0171.9 11.20
6.3
Fault table
Num-
ber
Type
Cause
Remedy
F15001
Warning
An error has been detected in the
runtime monitoring of the boom fold-
ing job computer.
•
Restart the implement
•
Check the boom folding job computer connection
cable
•
Check fuse F6
F15002
Note
Spraying pump speed is too low
•
Operate spraying pump at 540 rpm
F15003
Note
A cleaning step could not be com-
pleted with the defined conditions.
•
The required quantity of flushing
water cannot be withdrawn
•
Spray pressure does not drop
below 12 psi / 1 bar
•
Check the flushing water tank (fill level curve, fill
level sensor, etc.)
•
Check the pressure sensor for the spray line
(BWA011)
F15004
Warning Position detection signal for the rate
control valve is outside the permissi-
ble signal range of 4 to 20 mA
•
Check the connection line for the rate control
valve (KWA011)
•
Check fuse F2
•
Check the rate control valve (KWA011)
F15005
Alarm
The voltage of the axle potentiometer
is outside the permissible signal
range of 2 to 22 mA
•
Check the connection cable and potentiometer
on the drawbar.
F15006
Warning This text appears when exiting the
Diagnostics menu
---
F15007
Alarm
The voltage of the oil pressure sen-
sor is outside the permissible signal
range of 2 to 22 mA
•
Check the pressure sensor and connection cable
of the hydro accumulator.
F15008
Alarm
Failure of the front or rear tank fill
level indicator, automatic mode for fill
level control between the front and
rear tank is ended
•
Adjust the fill level ratio between the front tank
and rear tank
•
Check the fill level sensors and fill level curves.
F15009
Warning The fill level-dependent agitation
pressure cannot be maintained
•
Check the connection line and agitation pressure
valve (KWA045)
•
Check the agitator nozzles
•
Check the suction filter
F15010
Warning The signal of the agitation pressure
sensor is outside the permissible
signal range of 2 to 22 mA
•
Check the sensor and connection cable
F15011
Warning An error was detected at runtime
monitoring of the Comfort Package /
Comfort Package Plus job computer.
•
Restart the implement
•
Check the connection cable of the Comfort
Package/Comfort Package Plus job computer
•
Check fuse F7
F15012
Warning The voltage value of the potentiome-
ter on the suction tap is outside the
permissible signal range of 0.5 to 4.5
V (Comfort Package) or 2 to 22 mA
(Comfort Package Plus)
•
Check the sensor and connection cable
•
Check fuse F2
F15013
Warning Missing change of the voltage value
for the pressure sensor during simul-
taneous activation of the setting
motor
•
Check the connection line and agitation pressure
valve (KWA045)
•
Check the agitator nozzles
•
Check the suction filter