![Amazone Pantera 4503 Скачать руководство пользователя страница 110](http://html1.mh-extra.com/html/amazone/pantera-4503/pantera-4503_operating-manual_2919770110.webp)
Fault
110
ISOBUS field sprayer BAG0171.9 11.20
F15204
Warning
Induction bowl suction valve does not
send any messages
•
Check fuse F3
•
Contact your AMAZONE dealer
F15205
Warning
The yaw rate sensor has detected an
error
•
Check the sensor bracket - the sensor
must be firmly installed without vibration
•
Contact your AMAZONE dealer
F15206
Warning
The voltage of the oil pressure sensor is
outside the permissible signal range of 2
to 22 mA
•
Check the pressure sensor and connec-
tion cable
F15208
Warning
The current agitating pressure is higher
than the nominal agitating pressure for
longer than 10 seconds
•
Check the KWA045 agitator valve
•
Check the KWA045 agitator valve con-
nection cable
F15210
Alarm
The basis computer of the sprayer does
not receive any messages from the yaw
rate sensor
•
Check the connection cable and yaw
rate sensor
•
Check fuse F1 and F2
•
Check the settings in the Setup menu
F15211
Warning
The CurveControl yaw rate sensor has
detected an error
•
Check the sensor bracket - the sensor
must be firmly installed without vibration
•
Contact your AMAZONE dealer