92
ML-2350A/2351A
1. Setting Welding Schedules
⇒
When laser light is out of the set allowable energy range, a monitor error is
output.
Setting the Upper Limit Value of Lamp Input Power
Set the maximum value of power to be input into the flashlamp. Since the
performance of the flashlamp is gradually deteriorated, it is necessary to increase the
supply power little by little. When the supply power exceeds the value set here, a
screen to prompt you to replace the flashlamp is displayed.
(1) Press the "REFERENCE SETTING" setting button. Enter the ratio (%) of the
upper limit value of lamp input power.
⇒
If the laser welder is used in the status where 80% or more is displayed in "LAMP
INPUT POWER", the flashlamp replacement cycle may be shortened.
The set ratio of the upper limit value is registered. When the upper limit value is
exceeded, a screen to prompt the operator to replace the flashlamp is displayed.