3. Operating Procedure
125
ML-2350A/2351A
Chapter 3 Laser W
elding by Laser Controller (P
ANEL
CONTROL)
Introduction Part
Installation
and
Preparation
Part
Operating Part
Maintenance Part
Appendixes
⇒
For the laser output value, set the ratio (%) supposing that the set laser
output peak value is 100%. In this example, this peak value is 60% of "PEAK
POWER=5.00 kW", so that the actual laser output value is 3.0 kW. In this case,
even if "PEAK POWER=3.00 kW" and "FLASH1 03.6 ms 100%" are set, the
actual laser output value is the same.
⇒
For setting the number of continuous laser light outputs, set the number of
outputs per second in "REPEAT" in the range of 000 to 200 pps (pulse per
second). When 0 is set, a single output is performed.
⇒
For setting the number of laser light outputs, set it in "SHOT" in the range of
0000 to 9999. When "REPEAT" is not set to 0 and "SHOT" is 0, laser light is
continuously output until the LASER START/STOP button is pressed.
3
Outputting Laser Light
WARNING
Be sure to put on protective glasses for YAG Laser (1064 nm) during laser light
output operation. If laser light enters the eyes directly, a loss of eyesight may be
caused.
(1) Press the "STATUS" button to display the STATUS screen.
When Pin No.23 (control switching) of the EXT.I/O (1) connector remains in
an open state, external input signals are disabled and "PANEL CONTROL" is
displayed in "CONTROL DEVICE."
Содержание ML-2350A-CE
Страница 1: ...AA06OM1173714 18 OPERATION MANUAL YAG LASER WELDER ML CE 2350A 2351A Original instructions...
Страница 19: ...Introduction Part...
Страница 20: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 46: ......
Страница 57: ...Operating Part...
Страница 58: ......
Страница 118: ......
Страница 128: ......
Страница 150: ......
Страница 174: ......
Страница 179: ...Maintenance Part...
Страница 180: ......
Страница 209: ...Appendixes...
Страница 210: ......