142
ML-2350A/2351A
3. Connector Functions
REMOTE INTERLOCK Connector
The REMOTE INTERLOCK connector closes the branch shutter and connects
the interlock to cut off laser light in an emergency.
⇒
Use the following product out of the attached connectors.
Plug
Case
Manufacturer
116-12A10-2AF10.5
TAJIMI ELECTRONICS CO., LTD.
Pin No.
Description
1
When the section between pin No.1 and pin No.2 is put an open circuit, the branch
shutter is closed.
2
⇒
When the section between 2 pins of this connector is opened by operating the
external interlock, the resonator shutter and the branch shutter are closed and
both guide light and laser output are stopped. Connect this connector to the
main interlock, chamber interlock, door interlock, or other interlock. A multiple
number of these interlocks may be connected in series as required. At delivery,
the connector for short circuit is installed.
Inside of the laser
REMOTE INTERLOCK connector
+24V
External interlock
+5V
4.7k
1
2