Timing Chart
217
ML-2350A/2351A
2-powersharing ... Operation by laser controller (PANEL CONTROL)
The following diagram shows the lapse of time in the case where BEAM1 and BEAM2
to are set to ON on the laser controller and laser light is simultaneously output from
input unit 1 and input unit 2 after the branch shutter is opened.
*1 60s max.
Charging time. When a high voltage is turned ON and charging is
completed, the READY status is provided.
*2 150ms or more
Shutter operation time. After beam selection, a laser start input
signal is input after the lapse of certain time for shutter operation.
*3 40ms
Time required for the end signal to be output after a laser output.
*4 40ms
Time required for outputting a signal to indicate whether the laser
energy is within the set upper limit value (HIGH) and lower limit
value (LOW) of monitor output.
High Voltage ON Output
Ready Output
Beam Select 1 Input *
Beam Select 2 Input *
Laser Start Input *
(
Laser light)
End Output
Monitor Normal/
Trouble Output
(*: Operation on the user side)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Charging completed
60s max. (Charging time)
150ms or more
Laser beams are projected from
Laser Beam Input Units 1 and 2
*1
*2
*3
*4
40ms
(After a laser output, the charging status may lower.)
150ms or more *2
Laser beams are projected from
Laser Beam Input Unit 1
Introduction Part
Operating Part
Maintenance Part
Appendixes
Installation
and
Preparation
Part
Содержание ML-2350A-CE
Страница 1: ...AA06OM1173714 18 OPERATION MANUAL YAG LASER WELDER ML CE 2350A 2351A Original instructions...
Страница 19: ...Introduction Part...
Страница 20: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 46: ......
Страница 57: ...Operating Part...
Страница 58: ......
Страница 118: ......
Страница 128: ......
Страница 150: ......
Страница 174: ......
Страница 179: ...Maintenance Part...
Страница 180: ......
Страница 209: ...Appendixes...
Страница 210: ......