116
ML-2350A/2351A
4. Setting the Function of the Output Unit with Fiber Sensor (Option)
4. Setting the Function of the Output Unit with Fiber
Sensor (Option)
For using the output unit with fiber sensor (option), perform a setting to make the
function effective by the DIP switches provided in the side face of the main unit.
This section explains how to set the function of the output unit with fiber sensor.
The output unit with fiber sensor is provided with the following 3 functions.
Fiber breakage detection: Detects that the fiber was broken during laser output.
Fiber mount check:
Check that the fiber is correctly mounted in the output unit.
LED ON check:
Check that the HV-ON lamp of the output unit lights when
a high voltage is applied.
DIP switches are provided on the CPU board in the side surface and on the fiber
breaking sensor board in the top surface of the main unit. First, remove the cover
and set No.3 of SW2 provided on the CPU board to ON to enable the fiber breakage
detecting function. Next, set the fiber mount checking function and the LED ON
checking function by SW1 and SW2 provided on the fiber breaking sensor board in
the top surface.
Inside of the side surface of the main unit
Inside of the top surface of the main unit
Remove the screws of the side cover,
raise the cover, and pull it out forward.
Set the fiber breakage detecting
function by SW2.
1
2
3
4
5
6
7
8
O
F
F
SW2
Set the LED ON
checking function by
SW1.
Set the fiber mount
checking function by
SW2.
Содержание ML-2350A-CE
Страница 1: ...AA06OM1173714 18 OPERATION MANUAL YAG LASER WELDER ML CE 2350A 2351A Original instructions...
Страница 19: ...Introduction Part...
Страница 20: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 46: ......
Страница 57: ...Operating Part...
Страница 58: ......
Страница 118: ......
Страница 128: ......
Страница 150: ......
Страница 174: ......
Страница 179: ...Maintenance Part...
Страница 180: ......
Страница 209: ...Appendixes...
Страница 210: ......