3. Connector Functions
EXT.I/O (4) Connector (D-Sub 25 pin)
The EXT.I/O (4) connector inputs and outputs an emergency stop signal for the
laser and inputs an external interlock signal.
⇒
Use the following product out of the attached connectors.
Socket
Case
Manufacturer
HDBB-25S(05)
HDB-CTH(10)
HIROSE ELECTRIC CO., LTD.
Input Pins of EXT.I/O (4) Connector
Pin No.
Description
1
Emergency stop input 1
When the section between Pin No.1 and Pin No.8 is put in an open circuit, an
emergency stop is activated, the high voltage is turned off, the branch shutter is closed,
and the pump is stopped.
To cancel it, put the section between Pin No.1 and Pin No.8 and the section between
Pin No.2 and Pin No.6 in closed circuits and then input the trouble reset signal.
8
2
Emergency stop input 2
When the section between Pin No.2 and Pin No.6 is put in an open circuit, an
emergency stop is activated, the high voltage is turned off, the branch shutter is closed,
and the pump is stopped.
To cancel it, put the section between Pin No.1 and Pin No.8 and the section between
Pin No.2 and Pin No.6 in closed circuits and then input the trouble reset signal.
6
14
External interlock input 1
When the section between Pin No.14 and Pin No.15 is put in an open circuit, the branch
shutter is closed.
To cancel it, put the section between Pin No.14 and Pin No.15 and the section between
Pin No.16 and Pin No.17 in closed circuits and then input the trouble reset signal.
15
16
External interlock input 2
When the section between Pin No.16 and Pin No.17 is put in an open circuit, the branch
shutter is closed.
To cancel it, put the section between Pin No.14 and Pin No.15 and the section between
Pin No.16 and Pin No.17 in closed circuits and then input the trouble reset signal.
17
⇒
For simple systems, do not connect anything to pins not described above.
Emergency stop input 1 (in)
Emergency stop input 2 (in)
Emergency stop input 2 (in)
Emergency stop input 1 (in)
Emergency stop output 1 (out)
Emergency stop output 2 (out)
Emergency stop output 2 (out)
Emergency stop output 1 (out)
(in) External interlock input 1
(in) External interlock input 1
(in) External interlock input 2
(in) External interlock input 2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Содержание ML-2350A-CE
Страница 1: ...AA06OM1173714 18 OPERATION MANUAL YAG LASER WELDER ML CE 2350A 2351A Original instructions...
Страница 19: ...Introduction Part...
Страница 20: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 46: ......
Страница 57: ...Operating Part...
Страница 58: ......
Страница 118: ......
Страница 128: ......
Страница 150: ......
Страница 174: ......
Страница 179: ...Maintenance Part...
Страница 180: ......
Страница 209: ...Appendixes...
Страница 210: ......