CONTROL UNITS СU-TR230-868 / СU-TR400-868
24
24
SETTINGS
MENU
SETTING
dESCRIPTION
VaLUES
faCTORy
VaLUE
P8
f7
Operating time LOAD № 1 after the command
of the remote control LOAD № 1 ENABLE.
The
operating time of the outputs of the connectors
7
–
9
(value
13
,
tab.
14) is con
figure
d in the case
of recording the remote for load control (LOAD
command № 1,
tab.
4)
no
— load does not
turn off according
to time (it turns
off only at the
command of the
remote control)
01
,
02
…
99:
01
— 1 min
99
— 99 min
no.
f8
Operating time LOAD № 2 after the command
of the remote control LOAD № 2 ENABLE.
The
operating time of the outputs of the connectors
7
–
9
(value
14
,
tab.
14) is con
figure
d in the case
of recording the remote for load control (LOAD
command № 2,
tab.
4)
no
— load does not
turn off according
to time (it turns
off only at the
command of the
remote control)
01
,
02
…
99:
01
— 1 min
99
— 99 min
no.
P0
f0
Reset to factory settings.
See section ‘6.4. Reset to factory settings’
f1
Cycle counter.
See section ‘6.5. Cycle counter data’
Tab.
14 describes the operating modes of the outputs of connectors
7
–
9
(
fig.
8 / 9). When setting
the value (
P3
–
f4
…
f6
), the outputs of the connectors (relay contacts of the control unit) will
operate in accordance with the specified logic. The
figure
shows the normal status of the outputs
(relay contacts of the control unit).
JX.3
JX.2
JX.1
7-9
NO
NC
COM
NO
— normally open contact
NC
— normally closed contact
Table 14
VaLUE
dESCRIPTION
01
Signal lamp.
The activation will occur during movement and during the delay time (
P8
–
f2
,
tab.
13).
Fig.
19 is an example of connecting a signal lamp
02
Lighting lamp.
The activation will occur during movement and during the time after the
movement stops (
P8
–
f3
,
tab.
13). In the absence of movement, the lighting lamp can be
activated by a command from the radio remote control (control commands LIGHTING,
tab.
4) with setting the response time (
P8
–
f4
,
tab.
13).
Fig.
19 is an example of connecting a lighting lamp
03
One-way traffic light (iscription of full opening).
Activation will accur after full opening.
Fig.
20 is an example of connecting a traffic light
Содержание CU-TR230-868
Страница 2: ......
Страница 40: ......
Страница 78: ......
Страница 119: ...117 117 200 310 164 270 R40 90 118 244 271 350 377 2 3 ...
Страница 122: ...120 120 8 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 123: ...121 121 9 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 129: ......