CONTROL UNITS СU-TR230-868 / СU-TR400-868
19
19
SETTINGS
6.2.5. dELETING aLL REMOTES
f0 — dELETING aLL REMOTES
Y
Deleting all remotes recorded to the control unit is performed!
Table 12
1
Enter the setting menu (
tab.
3) and select the
P2
menu.
Select the
f0
setting. After the desired setting appears, press
2
After the inscription
dL
appears, press
and hold it for ~ 5 s until
a dot appears on the display, which will mean the deleting all remotes
5 s
3
After the inscription
f0
appears, to exit the setting menu,
press twice
×2
6.3
SETTING OPERaTION PaRaMETERS
Table
13 provides a description of the settings, setting values, and factory values upon delivery.
An example of performing is described in
tab.
3.
Table 13
MENU
SETTING
dESCRIPTION
VaLUES
faCTORy
VaLUE
P1
f0
Drive model selection.
The drive model with
encoder has a letter E
01
— with mechanical
switches
02
— with encoder
01.
f1
Setting the direction of the door opening.
See section ‘6.1. Setting the end position of doors’ item 2
f2
*
Setting the end positions of the drive with switches
.
See section ‘6.1. SETTING THE END POSITION OF DOORS’, item 3
f3
**
Setting the end positions of drive with ENCODER.
See section ‘6.1. Setting the end position of doors’, item 3
f4
***
Accurate setting of the end position
of opening (
LO
)
–f … 0 … f
Values with a ‘–’ sign ad-
just the position of doors
relative to value
0
(set
position) in the closing
direction, the rest — in
the opening direction
0.
f5
***
Accurate setting of the end position
of closing (
LC
)
f6
***
Accurate setting the shutdown position of
the
SE
input and/or slow speed (
LS
)
. It is
performed if the setting
P5
–
f7
or
P5
–
f9
is
enabled (
on
)
Содержание CU-TR230-868
Страница 2: ......
Страница 40: ......
Страница 78: ......
Страница 119: ...117 117 200 310 164 270 R40 90 118 244 271 350 377 2 3 ...
Страница 122: ...120 120 8 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 123: ...121 121 9 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 129: ......