CONTROL UNITS СU-TR230-868 / СU-TR400-868
22
22
SETTINGS
MENU
SETTING
dESCRIPTION
VaLUES
faCTORy
VaLUE
P5
f3
Operating time when opening
01
,
02
,
03
…
99
:
01
— 1 s
99
— 99 s
99.
f4
Operating time when closing
Y
In
P5
–
f3
and
P5
–
f4
, the time for continuous movement of doors between the end
positions is set. The operating time should be sufficient to fully open or close (it is
recommended that during setting to set the time more by 3–5 s). If the set operating time
is less than the time required to fully open / close the door, then the movement of the door
leaf stops after the operating time has expired.
f5
Opening time (reverse) after the safety
device is activated when closing.
It automati-
cally opens after activation the inputs
PH1
and
SE
(
tab.
2, connector 20), the built-in obstacle
detection system (
P5
–
f2
)
01
— opening
to end position
02
— opening ~2 s
03
— opening ~1 s
01.
f6
*
Sensitivity of obstacle detection at the
beginning of opening.
The setting allows
the system integrated in the control unit to
detect an obstacle at the very beginning of
the opening
no
— disabled
01
,
02
,
03
…
99
:
01
— min.
99
— max.
no.
**
f7
Disabling the safety edge near the floor.
When the setting is actuated, the operation
of the
SE
input (
tab.
2, connector 20) near the
floor will be disabled. For drives with switches,
the disabling position is set by the switch of
the drive connected to input
5.L
(
Figure
12).
For drives with an encoder, the disabling
position is set by the unit automatically from
the set end position of door closing; position
correction is possible (
P1
–
f6
)
no
— disabled
on
— enabled
no.
Y
The height from the floor, after which the operation of the
SE
input is disabled should be
less than 50 mm. After setting the edge disabling and any change (setting) in the end posi-
tion of the closed doors, it is necessary to verify to confirm compliance with the require-
ments of the safety standard (EN 12453). An object 50 mm high located on the floor should
be detected by contact with the lower edge of the door leaf (the doors will stop and open).
It is verified in the middle and at the edges of the door leaf
f8
*
Slow speed at the start of closing
no
— disabled
01
,
02
…
05
:
01
— 1 s
05
— 5 s
no.
f9
*
Slow speed near the floor.
When the setting is
enabled the position of slow speed starting is
set in the same way as for setting
P5
–
f7
(the
starting position of the settings is the same).
aTTENTION!
When the setting is on, please
check up that the door stops in the required
end positions (section 6.1 point 4).
no
— disabled
on
— enabled
no.
Содержание CU-TR230-868
Страница 2: ......
Страница 40: ......
Страница 78: ......
Страница 119: ...117 117 200 310 164 270 R40 90 118 244 271 350 377 2 3 ...
Страница 122: ...120 120 8 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 123: ...121 121 9 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 129: ......