CONTROL UNITS СU-TR230-868 / СU-TR400-868
21
21
SETTINGS
MENU
SETTING
dESCRIPTION
VaLUES
faCTORy
VaLUE
P3
f8
Operation of the
SBS
and
OP
inputs
(
tab.
2,
connector 20). When setting the outputs of
connectors 7–9 for two-way control (values
05
and
06
,
tab.
14), the input
SBS
can be used for
the direction of
ENTRY
, the input
OP
for the
direction of
EXIT
. The STEP BY STEP or OPEN
control commands correspond to the com-
mands of the radio remote control (
tab.
4)
01
—
02
—
03
—
SBS
STEP BY STEP
OP
OPEN
SBS
STEP BY STEP
OP
STEP BY STEP
SBS
OPEN
OP
OPEN
01.
P4
f1
Pause time before automatic closing
no
— disabled
01
,
02
,
03
…
99
:
01
— 1 s
99
— 99 s
no.
f2
Pause time before automatic closing
after
operation of the photocells connected to input
PH1
(
tab.
2, connector 20)
f3
Pause time before automatic closing
from
the partial opening position. It is executed if
the time for partial opening of doors has been
set (
P1
–
f9
)
f4
The pause time before automatic closing
from
the partial opening position after the photocells
connected to input
PH1
are actuated (
tab.
2,
connector 20). It is executed if the time for par-
tial opening of doors has been set (
P1
–
f9
)
Y
If automatic closing is enabled (pause time is set), the
PHOTOTEST
function (
P7
–
f3
–
on
setting) will be automatically enabled. Mandatory connection of photocells is required
(
fig.
16–18).
In the fully open position, when the pause time is counted to automatic closing, the
OPEN
command (buttons, connection inputs, radio remote controls) will reset the pause time
and start the countdown (
P4
–
f1
,
P4
–
f3
) from the beginning. When input
S
is activated
(
tab.
2, connector 20), the countdown to automatic closing will be reset and will start from
the beginning (
P4
–
f1
,
P4
–
f3
) when the input is restored. If the automatic closing is not set
after the photocells are activated (
P4
–
f2
–
no
,
P4
–
f4
–
no
), then the continuous operation
of the input
PH1
will lead to a countdown first after the end of the current pause count (the
operation does not interrupt the count). 3 s before the end of the pause time for automatic
closing, the traffic signal will be red, the signal lamp will be operated.
P5
f1
*
Sensitivity of obstacle detection when
opening.
When opening, the detection of an
obstacle will stop the movement
no
— disabled
01
,
02
,
03
…
99
:
01
— max.
99
— min.
no.
**
f2
*
Sensitivity of obstacle detection when
closing.
When closing, the detection of an
obstacle will cause it to stop and then open
again (opening value is set by
P5
–
f5
Y
Settings
f1
,
f2
,
f6
(menu
P5
) relate to the operation of the obstacle detection system inte-
grated in the control unit. The decision about the need to adjust and the settings of
f1
,
f6
(when opening) and
f2
(when closing) are carried out by qualified specialists (EN 12635) of
the competent organization. The settings can be used for added safety, for example, during
door closing additionally to safety contact edge or, for example, during door opening in
case there are apertures over 50 mm or protruding parts in the door leaf that a person can
grab or stand on. In case of use, the settings must ensure the safe and correct operation
of the drive system in accordance with the applicable regulatory documents (EN 12453),
excluding damage, false alarms. After setting, measurements are required according to the
methodology of regulatory documents
Содержание CU-TR230-868
Страница 2: ......
Страница 40: ......
Страница 78: ......
Страница 119: ...117 117 200 310 164 270 R40 90 118 244 271 350 377 2 3 ...
Страница 122: ...120 120 8 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 123: ...121 121 9 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 129: ......