56
•
MN-35947
•
Rev 15
•
01/18
•
Combitherm® CT PROformance™ and CT Classic Series Installation Manual
Installation
The CombiHood PLUS option is factory installed directly on the
top of the Alto-Shaam Combitherm CTP or CTC series oven.
• Using EPA method 202 testing, grease laden vapors emitted by
the Combi Ventless hood are 0.58 mg/m
3
– far less than U.L.’s
established standard of 5 mg/m
3
.
• A high-powered fan moves all steam and vapors from the oven
cavity into the hood intake and out the back exhaust vent,
trapping grease as the air moves through the fi lter system.
• As steam and vapors are circulated through the hood,
condensed steam drains at the back of the hood.
• An activated charcoal fi lter cleans the air before venting it out
the back of the hood.
• CombiHood PLUS™ performance is “smart”; engaging the fan
during the last two minutes of the cook cycle, which provides
quiet operation and consumes less power.
CombiHood Plus Washable Grease Filter with
metal housing (5017362)
Washing frequency should be based on oven usage with a maximum
of two weeks between cleaning if the oven is used for non-grease
laden products or steam applications only. Grease laden products
require cleaning frequency of at least once a week.
Remove the grease fi lter by pulling it straight out of the housing.
Place the fi lter in the dishwasher or wash separately by placing in
hot, soapy water until all grease and particles have been removed.
Rinse thoroughly. Allow the fi lter to air dry before reinstalling.
The air fl ow arrow on the fi lter casing should point toward the hood
fan when the fi lter is reinstalled.
CombiHood Plus Charcoal Filter with
paper housing, Class II (FI-25866)
CombiHood Plus Charcoal Filter with metal housing, Class I
required for New york City and Los Angeles
(FI-36620)
The charcoal fi lter should be inspected once a month for
contaminants. Replacement must be made at a minimum of three
month intervals — more oft en if heavy contaminants are visible or if
the fi lter no longer controls odors.
To remove the fi lter, pull and slide out while holding the bottom
housing. When replacing the fi lter, make certain the air fl ow
arrow(s) point toward the hood fan, and that the fi lter is replaced in
the three-sided metal frame provided with the hood.
To access the fi lters, swing the outer door
up until the hinges latch in place. Then turn
the three thumb screws
one quarter-turn
to release the inner door.
FRONT OF HOOD
ALIGNS WITH FRONT
OF COMBI DOOR
Condensate Drain
A condensate drain line
to the fl oor drain must be
installed. The drain line
must always be a positive
gradient away from the
Combitherm oven.
Test the drain for proper
drainage and signs of
leaking on a monthly
basis.
notICe:
A pressure switch is used to detect when the airfl ow through the charcoal fi lter is reduced by 25% - indicating a possible
blockage. This will generate an E101 error message on the oven control display. The fi lters will need to cleaned or replaced.
If the washable fi lter is not seated properly, an error code E102 appears on the oven control display during the selft est at the beginning of
a cooking cycle or during the last two minutes of a cooking cycle.
When an E101 or E102 appears on the control display, a cook cycle cannot be started until the cause of the fault has been fi xed.