eleCtriCal
(no CorD, no PluG - DeDiCateD CirCuit reQuireD)
MODEL
VOLTAGE
PH
HZ
AMPS
kW
BREAKER
AWG
CONNECTION
CTC6-10E
208 – 240
3
50/60
21.9 – 25.3
7.9 – 10.5
25 - 30
8
L1, L2, L3, G
380 – 415
3
50/60
13.4 – 14.6
9.0 – 10.5
16
8
L1, L2, L3, N, G
440 – 480
3*
50/60
11.6 – 12.6
9.1 – 10.5
15
10 – 8
L1, L2, L3, G
*ELECTRICAL SERVICE CHARGE APPLIES
WeiGHt
SHiP DimenSionS
Pan CaPaCitY
NET
524 lbs est
238 kg
(L x W x H) 58" x 45" x 51"*
FULL–SIZE:
20" x 12" x 2-1/2"
Seven (7)
PRODUCT MAXIMUM: 72 lb (33 kg)
SHIP
608 lbs*
276 kg*
(1473 x 1143 x 1295mm)*
GN 1/1:
530 x 325 x 65mm
Seven (7)
VOLUME MAXIMUM: 45 quarts (57 liters)
*DOMESTIC GROUND SHIPPING INFORMATION. CONTACT FACTORY
FOR EXPORT WEIGHT AND DIMENSIONS.
*HALF–SIZE SHEET:
18" x 13" x 1"
Seven (7)
**ON WIRE SHELVES ONLY. ADDITIONAL WIRE
SHELVES REQUIRED FOR MAXIMUM CAPACITY
DimenSionS: H x W x D
eXterior:
35-1/8" x 35-11/16" x 41-7/16" (892mm x 906mm x 1053mm)
eXterior WitH reCeSSeD Door:
35-1/8" x 40-11/16" x 41-7/16" (892mm x 1033mm x 1053mm)
interior:
20-1/2" x 16-1/4" x 28-1/16" (520mm x 411mm x 712mm)
CTC6-10E
ELECTRIC BOILER-FREE
Water reQuirementS
Water QualitY StanDarDS
tWo (2) ColD Water inletS - DrinKinG QualitY*
one (1) treateD Water inlet: 3/4" NPT connection. Line pressure 30 psi minimum dynamic and
90 psi maximum static (200 to 600 kPa) at a minimum flow rate of 0.26 gpm (1 L/min).
one (1) untreateD Water inlet: 3/4" NPT connection. Line pressure 30 psi minimum dynamic and
90 psi maximum static (200 to 600 kPa) at a minimum flow rate of 2.64 gpm (10 L/min).
* Both inlets can be from same source. Divide using a manifold. Run one side through treatment device before running to oven.
Must meet line pressure and flow rate specifications for both inlets.
Water Drain: 1-1/2" (40mm) connection with a vertical vent to extend above the exhaust vent.
materials must withstand temperatures up to 200°F (93°C).
It is the sole responsibility of the owner/operator/purchaser of this equipment
to verify that the incoming water supply is comprehensively tested and
if required, a means of “water treatment” provided that would meet
compliance requirements with the published water quality standards shown
below. Non-compliance with these minimum standards will potentially
damage this equipment and/or components and void the original equipment
manufacturer’s warranty. Alto-Shaam recommends using OptiPure
®
[www.
optipurewater.com] products to properly treat your water.
Contaminant
Free Chlorine
Hardness
Chloride
pH
Silica
Total Dissolved Solids (tds)
inlet Water requirements
Less than 0.1 ppm (mg/L)
30-70 ppm
Less than 30 ppm (mg/L)
7.0 to 8.5
Less than 12 ppm (mg/L)
Treated line: 50-125 ppm
Untreated line: 50-360 ppm
ClearanCe reQuirementS
left:
0" (0mm)
18" (457mm) recommended service access
riGHt:
0" (0mm) Non-combustible surfaces
2" (51mm) door swing or combustible surfaces
toP:
20" (508mm) for air movement
bottom:
5-1/8” (130mm) for legs, air aintake
baCK:
4" (102mm)
4-5/16” (109mm) optional plumbing kit
inStallation reQuirementS
• Oven must be installed level.
• Hood installation is required.
• Water supply shut-off valve and back-flow preventer when required by local code.
E
C
D
B
A
60-9/16" (1538mm)
41-7/16" (1053mm)
39-1/4"
(996mm)
E: 6-11/16" (168mm)
E: 4-1/2" (114mm)
28-3/4"
(730mm)
26-3/16"
(665mm)
35-11/16" (906mm)
6" (152mm)
4" (102mm)
C: 6-1/2"
(165mm)
D: 3-5/16"
(84mm)
B: 2-1/2"
(63mm)
C: 9-1/2"
(240mm)
B: 12-3/4"
(324mm)
A: 18-1/4"
(464mm)
D: 5-1/2"
(139mm)
A: 6"
(153mm)
4"
(102mm)
35-1/8"
(892mm)
A = Untreated water
B = Treated water
C = Electrical (Back)
D = Water Drain
E = Electrical (Bottom)
Front
Back
Top/Bottom