26
•
MN-35947
•
Rev 15
•
01/18
•
Combitherm® CT PROformance™ and CT Classic Series Installation Manual
#425 - 01/18
DUE TO ONGOING PRODUCT IMPROVEMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
WWW.ALTO-SHAAM.COM
eleCtriCal - CtP6-10e
(no CorD, no PluG, DeDiCateD CirCuit reQuireD)
WITH COMBISMOKER
®
OPTION
ECO STANDARD
**PROpower™ OPTION
ECO STANDARD
**PROpower™ OPTION
VOLTAGE
PH
HZ
AWG
CONNECTION
AMPS
kW
BREAKER
AMPS
kW
BREAKER
AMPS
kW
BREAKER
AMPS
kW
BREAKER
208 – 240
1*
50/60
6
L1, L2/N, G
37.9 – 43.8
7.9 – 10.5
40 – 50
44.2 – 51.3
9.2 – 12.3
45 – 60
40.4 – 46.6 8.4 – 11.2
40 – 50
46.7 – 54.1
9.7 – 13
50 – 60
208 – 240
3
50/60
8
L1, L2, L3, G
21.9 – 25.3
7.9 – 10.5
25 – 30
28.4 – 32.6
9.2 – 12.3
30 – 35
24.4 – 28.1 8.4 – 11.2
25 – 30
30.9 – 35.5
9.8 – 13
35 – 40
380 – 415
3
50/60
8
L1, L2, L3, N, G
13.4 – 14.6
9 – 10.5
16
20.3 – 22.1
10.3 – 12.3
32
16.1 – 17.5 9.6 – 11.2
16 – 32
22.9 – 25
10.9 – 13
32
440 – 480
3*
50/60 10 – 8
L1, L2, L3, G
11.6 – 12.6
9.1 – 10.5
15
15 – 16.7
10.4 – 12.3
15 – 20
12.9 – 14.1 9.6 – 11.2
15
16.3 – 18.2
11 – 13
20
*ELECTRICAL SERVICE CHARGE APPLIES
**NO-COST OPTION ON ELECTRIC MODELS
WeiGHt
Pan CaPaCitY
STANDARD MODEL
WITH COMBISMOKER
®
OPTION
NET
SHIP
524 lbs EST
608 lbs*
238 kg
276 kg*
FULL–SIZE:
20" x 12" x 2-1/2"
Seven (7)
Six (6)
GN 1/1:
530 x 325 x 65mm
Seven (7)
Six (6)
**
HALF–SIZE SHEET
:
18" x 13" x 1"
Seven (7)
Seven (7)
SHiP DimenSionS
ProDuCt CaPaCitY
(L x W x H)
58" x 45" x 51"*
PRODUCT MAXIMUM
72 lb (33 kg)
(1473mm x 1143mm x 1295mm)*
VOLUME MAXIMUM
45 quarts (57 liters)
*DOMESTIC GROUND SHIPPING INFORMATION. CONTACT
FACTORY FOR EXPORT WEIGHT AND DIMENSIONS.
**ON WIRE SHELVES ONLY. ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
Water reQuirementS
Water QualitY StanDarDS
tWo (2) ColD Water inletS - DrinKinG QualitY*
one (1) treateD Water inlet: 3/4" NPT connection. Line pressure 30 psi minimum dynamic and
90 psi maximum static (200 to 600 kPa) at a minimum flow rate of 0.26 gpm (1 L/min).
one (1) untreateD Water inlet: 3/4" NPT connection. Line pressure 30 psi minimum dynamic and
90 psi maximum static (200 to 600 kPa) at a minimum flow rate of 2.64 gpm (10 L/min).
* Both inlets can be from same source. Divide using a manifold. Run one side through treatment device before running to oven.
Must meet line pressure and flow rate specifications for both inlets.
Water Drain: 1-1/2" (40mm) connection with a vertical vent to extend above the exhaust vent.
materials must withstand temperatures up to 200°F (93°C).
It is the sole responsibility of the owner/operator/purchaser of this equipment
to verify that the incoming water supply is comprehensively tested and
if required, a means of “water treatment” provided that would meet
compliance requirements with the published water quality standards shown
below. Non-compliance with these minimum standards will potentially
damage this equipment and/or components and void the original equipment
manufacturer’s warranty. Alto-Shaam recommends using OptiPure
®
[www.
optipurewater.com] products to properly treat your water.
Contaminant
Free Chlorine
Hardness
Chloride
pH
Silica
Total Dissolved Solids (tds)
inlet Water requirements
Less than 0.1 ppm (mg/L)
30-70 ppm
Less than 30 ppm (mg/L)
7.0 to 8.5
Less than 12 ppm (mg/L)
Treated line: 50-125 ppm
Untreated line: 50-360 ppm
ClearanCe reQuirementS
left:
0" (0mm)
18" (457mm) recommended service access
riGHt:
0" (0mm) Non-combustible surfaces
2" (51mm) door swing or combustible surfaces
toP:
20" (508mm) for air movement
bottom:
5-1/8” (130mm) for legs, air aintake
baCK:
4" (102mm)
4-5/16” (109mm) optional plumbing kit
inStallation reQuirementS
• Oven must be installed level.
• Hood installation is required.
• Water supply shut-off valve and back-flow preventer when required by local code.
DimenSionS: H x W x D
eXterior:
35-1/8" x 35-11/16" x 41-7/16" (892mm x 906mm x 1053mm)
eXterior WitH reCeSSeD Door:
35-1/8" x 40-11/16" x 41-7/16" (892mm x 1033mm x 1053mm)
interior:
20-1/2" x 16-1/4" x 28-1/16" (520mm x 411mm x 712mm)
CTP6-10E
ELECTRIC BOILER-FREE
A = Untreated water
B = Treated water
C = Electrical (Back)
D = Water Drain
E = Electrical (Bottom)
Front
Back
Top/Bottom