39
Installation
SITE INSTALLATION
mINImum CLEARANCE REQuIREmENTS
left side
0" (0mm)
minimum
18" (457mm)
recommended service access
right side
0" (0mm)
from
non
-
combustible
surfaces
2" (51
mm
)
from
combustible
surfaces
2" (51
mm
)
for
door
swing
back
4" (102mm)
for plumbing
4-5/16" (109mm)
for optional plumbing kit
top
20" (508mm)
for air movement
bottom
5-1/8" (457mm)
for legs and unobstructed air intake
NOTICE:
• A minimum distance of 18" (457mm) is strongly recommended for service access. If adequate service
clearance is not provided, it will be necessary to disconnect the gas, water, and drain to move the oven
with a fork lift for service access. Service charges in connection with inadequate service access is not
covered under warranty.
• do not install a stacked combination directly over a drain. Steam rising up out of the drain will
adversely affect operation, hamper cooling air circulation, and may damage electrical and electronic
components. Failure to do so will void the warranty. A single oven installed on a stand with solid
surface bottom shelf can be positioned over a drain since the solid surface will block the rising steam.
4" (102mm) for plumbing
4-5/16" (109mm) with optional plumbing kit
18
" (457mm)
for ser
vic
e ac
cess
0" (0mm) fr
om non-c
ombus
tible surf
ac
es
2" (51mm)
from c
ombus
tible surf
ac
es
2" (51mm) f
or door swing
pOSITIONINg ON SITE – COuNTERTOp
Place the oven on a stable, non-combustible level horizontal
surface. Use the adjustable feet to overcome an uneven floor and
ensure that the unit is level.
It is strongly recommended that table top models be mounted on a
factory supplied stand or a stand that is stable, open, and level. The
adjustable oven legs should be extended beyond the depth of the
positioning ring to allow for leveling after the oven has been placed
on the stand.
Each of the legs on the stand and the
oven can be adjusted
2" (51mm) up or down.
Level the oven from front-to-back and
side-to-side by means of the adjustable
legs. Components within the oven
condenser tank are sensitive to pitch
and can be can can be damaged. The tolerance to level
is +/- .125". If this tolerance range is not achievable, the
floor must be repaired to
obtain level.
Adjustable
Leg
Adjustable
Leg
Positioning
Ring
Positioning
Rings