eleCtriCal - CtP10-20e
(no CorD, no PluG, DeDiCateD CirCuit reQuireD)
WITH COMBISMOKER
®
OPTION
ECO STANDARD
**PROpower™ OPTION
ECO STANDARD
**PROpower™ OPTION
VOLTAGE
PH
HZ
AWG
CONNECTION
AMPS
kW
BREAKER
AMPS
kW
BREAKER
AMPS
kW
BREAKER
AMPS
kW
BREAKER
208 – 240
3 50/60 2 – 1
L1, L2, L3, G
68.8 – 79.4
24.8 – 33
70 – 80
88.7 – 102.3 28.9 – 38.5 90 – 110
71.3 – 82.3 25.3 – 33.7 80 – 90 91.2 – 105.2 29.4 – 39.2 100 – 110
380 – 415
3 50/60 4 – 3
L1, L2, L3, N, G
42.1 – 45.8
28.2 – 33
63
63.2 – 68.8 32.3 – 38.5
63 – 80
44.8 – 48.7 28.8 – 33.7
63
65.8 – 71.6 32.9 – 39.2
100
440 – 480
3* 50/60 6 – 4
L1, L2, L3, G
36.4 – 39.7
28.3 – 33
40
46.9 – 51.2 32.4 – 38.5
50 – 60
37.7 – 41.1 28.8 – 33.7 40 – 50
48.2 – 52.6 33 – 39.2
50 – 60
*ELECTRICAL SERVICE CHARGE APPLIES
**NO-COST OPTION ON ELECTRIC MODELS
WeiGHt
Pan CaPaCitY
STANDARD MODEL
WITH COMBISMOKER
®
OPTION
NET
760 lbs EST
345 kg
FULL–SIZE:
20" x 12" x 2-1/2"
Twenty-two (22)
Twenty-one (21)
GN 1/1:
530 x 325 x 65mm
Twenty-two (22)
Twenty-one (21)
SHIP
805 lbs*
365 kg*
GN 2/1:
650 x 530 x 65mm
Eleven (11)
Ten (10)
**FULL-SIZE SHEET:
18" x 26" x 1"
Eleven (11)
Eleven (11)
SHiP DimenSionS
ProDuCt CaPaCitY
(L x W x H)
56" x 49" x 65"*
PRODUCT MAXIMUM
240 lb (109 kg)
(1422mm x 1245mm x 1651mm)*
VOLUME MAXIMUM
150 quarts (190 liters)
*DOMESTIC GROUND SHIPPING INFORMATION. CONTACT
FACTORY FOR EXPORT WEIGHT AND DIMENSIONS.
**ON WIRE SHELVES ONLY. ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
Water reQuirementS
Water QualitY StanDarDS
tWo (2) ColD Water inletS - DrinKinG QualitY*
one (1) treateD Water inlet: 3/4" NPT connection. Line pressure 30 psi minimum dynamic and
90 psi maximum static (200 to 600 kPa) at a minimum flow rate of 0.53 gpm (2 L/min).
one (1) untreateD Water inlet: 3/4" NPT connection. Line pressure 30 psi minimum dynamic and
90 psi maximum static (200 to 600 kPa) at a minimum flow rate of 2.64 gpm (10 L/min).
* Both inlets can be from same source. Divide using a manifold. Run one side through treatment device before running to oven.
Must meet line pressure and flow rate specifications for both inlets.
Water Drain: 1-1/2" (40mm) connection with a vertical vent to extend above the exhaust vent.
materials must withstand temperatures up to 200°F (93°C).
It is the sole responsibility of the owner/operator/purchaser of this equipment
to verify that the incoming water supply is comprehensively tested and
if required, a means of “water treatment” provided that would meet
compliance requirements with the published water quality standards shown
below. Non-compliance with these minimum standards will potentially
damage this equipment and/or components and void the original equipment
manufacturer’s warranty. Alto-Shaam recommends using OptiPure
®
[www.
optipurewater.com] products to properly treat your water.
Contaminant
Free Chlorine
Hardness
Chloride
pH
Silica
Total Dissolved Solids (tds)
inlet Water requirements
Less than 0.1 ppm (mg/L)
30-70 ppm
Less than 30 ppm (mg/L)
7.0 to 8.5
Less than 12 ppm (mg/L)
Treated line: 50-125 ppm
Untreated line: 50-360 ppm
ClearanCe reQuirementS
left:
0" (0mm)
18" (457mm) recommended service access
riGHt:
0" (0mm) Non-combustible surfaces
2" (51mm) door swing or combustible surfaces
toP:
20" (508mm) for air movement
bottom:
5-1/8” (130mm) for legs, air aintake
baCK:
4" (102mm)
4-5/16” (109mm) optional plumbing kit
inStallation reQuirementS
• Oven must be installed level.
• Hood installation is required.
• Water supply shut-off valve and back-flow preventer when required by local code.
DimenSionS: H x W x D
eXterior: 45-11/16" x 43-3/4" x 46-3/16" (1160mm x 1111mm x 1173mm)
eXterior WitH reCeSSeD Door:
45-11/16" x 48-3/4" x 46-3/16" (1160mm x 1238mm x 1173mm)
interior:
31-1/2" x 24-1/4" x 32-3/4" (800mm x 616mm x 832mm)
CTP10-20E
ELECTRIC BOILER-FREE
B
E
C
D
A
6" (152mm)
4" (102mm)
C: 6-1/2"
(165mm)
D: 3-5/16"
(84mm)
D: 5-5/8"
(143mm)
B: 26-3/4"
(679mm)
C: 13-15/16"
(354mm)
C: 21-1/4"
(539mm)
A: 30-3/16"
(766mm)
A,B: 5-5/8"
(143mm)
43-3/4" (1111mm)
4"
(102mm)
45-11/16"
(1160mm)
E: 6-11/16" (168mm)
E: 5-3/8" (136mm)
73 5/16" (1863mm)
46-3/16" (1173mm)
30-13/16"
(783mm)
34-1/4"
(870mm)
47-7/16"
(1205mm)
A = Treated water
B = Untreated water
C = Electrical (Back)
D = Water Drain
E = Electrical (Bottom)
Front
Back
Top/Bottom
Содержание CT CLASSIC CTC10-10E
Страница 31: ...MN 35947 Rev 15 01 18 Combitherm CT PROformance and CT Classic Series Installation Manual 31 ...
Страница 80: ......