PHM821N_SVG
= Power
= Neutral
7
6
5
4
3
2
1
1.
External Supply Power Output
2.
Internal Control Transformer
3.
RELAY COM Terminal
4.
External Dispenser Input Signal Common
5.
Red Jumper Wire
6.
24VAC Terminal
7.
24VAC COM Terminal
Figure 32
Chemical Injection Using External AC Power Source
NOTE: An External AC Power Source is NOT provided
by Alliance Laundry Systems.
NOTE: Power for external supplies must not be derived
from the high-voltage main power connection point.
IMPORTANT: The external power must supply power of
240VAC or less and be protected at 3 Amps or less.
1.
Remove the red jumper wire installed by the factory between
“24VAC”, and “RELAY COM”.
2.
Connect one side of the external power to the “RELAY
COM” and the other to the external dispenser input signals
common. Refer to
Figure 33
.
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
64
Part No. F8429301ENR15