North American Approval
20 Pound Capacity Models (North American Approval)
Voltage Designation
Specifications
Code
Voltage
Cycle
Phase
Wire
Full
Load
Amps
Circuit
Break-
er
AWG
mm2
F and V-Speed Models
(unless otherwise noted)
B (F-speed)
120
60
1
2
7
15
14
2.5
B (V-speed)
120
60
1
2
8
15
14
2.5
X
200-208
50/60
1/3
2/3
4/3
15
14
2.5
220-240
Q
Standard
200-208
50/60
3
3
3
15
14
2.5
Electric
Heat
220-240
21
30
10
6.0
N
440–480
50/60
3
3
2
15
14
2.5
P
Standard
380–415
50/60
3
3
2
15
14
2.5
Electric
Heat
13
15
14
2.5
NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.
Table 25
30 Pound Capacity Models (North American Approval)
Voltage Designation
Specifications
Code
Voltage
Cycle
Phase
Wire
Full
Load
Amps
Circuit
Break-
er
AWG
mm2
F and V-Speed Models
(unless otherwise noted)
B
120
60
1
2
16
20
12
4
X (F-speed)
200–208
50/60
1/3
2/3
5/4
15
14
2.5
220-240
X (V-speed)
200-208
50/60
1/3
2/3
6/4
15
14
2.5
220-240
Table 26
continues...
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
52
Part No. F8429301ENR15
Содержание SCB040GNF
Страница 2: ......