5.
Clean customer-supplied steam filter, where applicable. Refer
to
Figure 43
.
a. Turn off steam supply and allow time for the valve to
cool.
b. Unscrew cap.
c. Remove element and clean.
d. Replace element and cap.
H042I_SVG
2
1
1.
Cap
2.
Steam Filter Element
Figure 43
6.
Check the bearing mounting bolts to make sure they are tor-
qued properly. Refer to
Torque
.
Torque, ft-lbs.
Model
Bearing
Torque
20
All
41
30-40
All
101
60
All
201
80-100
All
357
Table 43
7.
Tighten motor mounting bolt locknuts and bearing bolt lock-
nuts.
8.
Vacuum lint from motor vents.
9.
Clean all electronic boards of moisture and dust with canned
air.
10.
Verify the insulation is intact on all external wires and that all
connections are secure. If bare wire is evident, call a service
technician.
11.
Clean inverter drive cooling fan blades (where applicable).
Maintenance
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
74
Part No. F8429301ENR15
Содержание SCB040GNF