PHM823N_SVG
= Power
= Neutral
5
4
3
2
1
1.
External Supply Power Output
2.
Red Jumper Wire
3.
External Supply Input Signal Common
4.
VAC Power Terminal
5.
VAC RETURN Terminal
Figure 33
CAUTION
Do not attempt to increase fuse rating or alter wiring
of external chemical supply terminal strip in such as
way that may conflict with the suggested methods
provided on the Optional External Supply Wiring Dia-
gram.
W699
External Supply Signals
Wash-cycle signals are provided to the external chemical supply
equipment and a “wait for the next step” signal can be received
from the supply equipment.
For example, if ES1 is selected the K1 contact will close and
power will be supplied to Supply 1 Signal. The contact will re-
main closed for the amount of time programmed in control. Refer
to
Figure 34
for Internal Supply Connection or
Figure 35
for Ex-
ternal AC Connection.
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
65
Part No. F8429301ENR15