IMPORTANT: Increasing the drain hose length, instal-
ling elbows, or causing bends will decrease drain flow
rates and increase drain times, impairing machine per-
formance.
NOTE: Installation of additional machines will require
larger drain connections. Refer to
Drain Line Sizing /
Minimum Drain ID
.
Drain Information
Specification
20
30
40
60
80
100
Drain connection size, in. [mm]
2 [51]
2 [51]
3 [76]*
3 [76]*
3 [76]*
3 [76]*
Overflow drain connection size,
in. [mm]
1.5 [457]
1.5 [457]
1.5 [457]
1.5 [457]
2.25 [686]
2.25 [686]
Number of drain outlets
1
1
1
1
1
1
Drain flow capacity, gal/min
[l/min]
25 [95]
30 [114]
40 [151]
50 [189]
55 [208]
55 [208]
Recommended drain pit size, ft
3
[l]
2.0 [57]
2.5 [71]
3.5 [128]
5.7 [99]
8.0 [221]
9.5 [269]
* Also works with 3 in. [76 mm] OD PVC pipe if connected to inside of drain tee connector.
Table 20
Drain Line Sizing / Minimum Drain ID, in. [mm]
Model
Number of Machines
1
2
3
4
5
20
2 [50]
3 [76]
3 [76]
4 [102]
4 [102]
30
2 [50]
3 [76]
3 [76]
4 [102]
4 [102]
40
3 [76]
4 [102]
4 [102]
4 [102]
6 [152]
60
3 [76]
4 [102]
4 [102]
4 [102]
6 [152]
80-100
3 [76]
6 [152]
6 [152]
8 [203]
8 [203]
Table 21
Water Connection Requirements
WARNING
To prevent personal injury, avoid contact with inlet
water temperatures higher than 125° Fahrenheit [51°
Celsius] and hot surfaces.
W748
The maximum water inlet temperature for vended models is
125°F [51°C]and the recommended maximum water inlet tem-
perature for on-premises models is 150°F [66°C] (standard mod-
els) or 140°F [60°C] (WRAS approved models) .
Connections should be supplied by a hot and a cold water line of
at least the sizes shown in
Water Supply Line Sizing
. Installation
of additional machines will require proportionately larger water
lines.
Connections should be supplied by a hot and a cold water line per
national and local codes and in accordance with AS/NZS 3500.I.
To connect water service to a machine with hoses, use the follow-
ing procedure:
1.
Before installing hoses, flush the building’s water system at
the machine connection valves for at least two (2) minutes.
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
46
Part No. F8429301ENR15
Содержание SCB040GNF