IMPORTANT: DO NOT remove the red jumper wire from
the terminal strip.
EXTERNAL DISPENSER CONNECTIONS
RELAY COM
RELAY
COM
Supply 1
External
Dispensing
System
Internal
Supply
300mA Max
24VAC COM
24VAC COM
JUMPER FOR INTERNAL
24 VAC SUPPLY
CONNECTED TO RELAY
COM. (REMOVE IF NOT
WIRING TO INTERNAL
24 VAC SUPPLY
STEP 1:
Insert screwdriver & press down
to open cage clamp.
STEP 2:
Insert Wire
8.5mm
Strip Length
Wire Size 28-16AWG
0.08-1.5mm
24VAC
RED
ES 1
ES 2
ES 3
ES 4
EXAMPLE FOR EXTERNAL
DISPENSER CONNECTION
CHM2336N_SVG
4
3
2
1
1.
Relay Com
2.
Red Jumper Wire
3.
24 VAC
4.
Transformer
Figure 31
There are 3 terminals necessary for this connection option.
• Terminal “24VAC COM” is used to connect one side of the
internal control transformer to the external dispenser input
signals common.
• The second terminal is used to connect the other side of the
control transformer to the machine output signals common
through a red jumper wire between “24VAC” and “RELAY
COM”. Refer to
Figure 32
.
IMPORTANT: Do not use the transformer terminals if
an external power supply is used.
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
63
Part No. F8429301ENR15