30 Pound Capacity Models (North American Approval)
Voltage Designation
Specifications
Code
Voltage
Cycle
Phase
Wire
Full
Load
Amps
Circuit
Break-
er
AWG
mm2
Q
Standard
200–208
50/60
3
3
4
15
14
2.5
Electric
Heat
220-240
22
30
10
6.0
N
440–480
50/60
3
3
3
15
14
2.5
P
Standard
380–415
50/60
3
3
3
15
14
2.5
Electric
Heat
13
15
14
2.5
NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.
Table 26
40 Pound Capacity Models (North American Approval)
Voltage Designation
Specifications
Code
Voltage
Cycle
Phase
Wire
Full
Load
Amps
Circuit
Break-
er
AWG
mm2
F and V-Speed Models
(unless otherwise noted)
B
120
60
1
2
16
20
12
4
X (F-speed)
200–208
50/60
1/3
2/3
6/4
15
14
2.5
220-240
X (V-speed)
200–208
50/60
1/3
2/3
7/4
15
14
2.5
220-240
Q
Standard
200-208
50/60
3
3
4
15
14
2.5
Electric
Heat
220-240
42
50
8
10.0
N
Standard
440-480
50/60
3
3
3
15
14
2.5
Electric
Heat
22
30
10
6.0
Table 27