Installation
Pallet Jack Cover Plate Removal (80
and 100 Pound Models Only)
Prior to installing an 80 and 100 pound machine, the optional pal-
let jack cover plate can be removed in preparation of re-installing
to machine base frame after machine installation.
1.
Locate cover plate on back panel.
2.
Remove back panel.
3.
Remove all hardware holding cover plate on back panel, refer
to
Figure 14
. DO NOT DISCARD HARDWARE.
4.
Remove cover plate.
CHM2400N_SVG
4
3
2
1
1
1.
Nut
2.
Stud
3.
Cover Plate
4.
Back Panel
Figure 14
5.
Re-install back panel.
NOTE: Refer to
Pallet Jack cover Plate Installation (80 and
100 Pound Models Only)
section to install cover plate to
machine base after machine installation.
Single Machine Foundation Require-
ments
A minimum 3500 psi (refer to rating per supplier) reinforced con-
crete set on a prepared bed is required for all new machine instal-
lations.
NOTE: Do not mount on wooden floors, tile floors, ele-
vated floor levels, stacked multiple base frames, or
over basements or crawl spaces because of the high
extract speed and the G-forces exerted. For 80 pound
models and larger, do not mount on metal base frames.
Thoroughness of detail must be stressed with all foundation work
to ensure a stable unit installation, eliminating possibilities of ex-
cessive vibration during extract.
WARNING
To reduce the risk of fire, serious injury, property
damage and/or death, install the machine on a level
(within 3/8 inch), uncovered concrete floor of suffi-
cient strength at grade.
W787
For new foundations a mounting bolt template or an elevated
metal base frame is available at extra cost. For all installations a
concrete hardware kit is available at extra cost.
The machine must be anchored to a smooth level surface so that
the entire base of the machine is supported and rests on the
mounting surface.
IMPORTANT: Do not permanently support the machine
on only four points with spacers. Grouting is required
and spacers must be removed.
Machine Installation with Existing Floor
The existing floor slab must meet minimum requirements shown
in
Machine Foundation and Pad Installation
per machine model.
The floor must be reinforced concrete without voids under slab.
If the floor meets these requirements and an elevated pad is NOT
desired, refer to
Figure 1
6
and proceed to
Machine Mounting and
Grouting
section.
Elevated Pad Installation with Existing Floor
The existing floor slab must meet minimum requirements shown
in
Machine Foundation and Pad Installation
per machine. The
floor must be reinforced concrete without voids under slab. If the
slab meets these requirements and an elevated pad is desired, re-
fer to
Figure
17
and proceed to
Machine Foundation and Pad In-
stallation
section.
Elevated Base Frame Installation with Existing Floor
The existing floor slab must meet minimum requirements shown
in
Machine Foundation and Pad Installation
per machine. The
floor must be reinforced concrete without voids under slab. If the
slab meets these requirements and an elevated base frame is de-
sired, refer to
Figure 1
6
and
Figure
18
and proceed to
Machine
Mounting and Grouting
section.
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
35
Part No. F8429301ENR15
Содержание SCB040GNF
Страница 2: ......