Cast-in-place Anchors (refer to
Table 18
)
CHM2438N_SVG
5
A
D
E
B
C
1
2
4
3
1.
Machine Frame Base
2.
Grout
3.
Anchor Bolt (minimum Grade 5 SAE rating)
4.
Concrete
5.
Edge of Pad
Figure 20
Minimum Anchoring Specifications, in. [mm]
Description
20-40
60
80-100
Number of Bolts
4 or 6*
6
6
A
Bolt Length
6 [152]
6 [152]
8.75 [216]
B
Thread Extension
2.5 [64]
2.5 [64]
2.75 [64]
C
Bolt Diameter
5/8 [16]
5/8 [16]
3/4 [19]
D
Embedment Depth
3.5 [89]
3.5 [89]
6 [152]
E
Distance from Bolt Center to Edge of
Concrete Pad
Refer to
Table 8
Refer to
Table 8
Refer to
Table 11
* On 20-40 pound models, the four (4) corner bolts are required and the two (2) center bolts are optional when mounting a machine
or elevated base frame to floor.
Table 18
Floor Load Data
Specification
20
30
40
60
80
100
Static floor load, lbs. [kN]
420 [1.87]
570 [2.54]
700 [3.11]
940 [4.18]
1550 [6.89]
1670 [7.51]
Static pressure, lbs.-ft
2
[kN-m
2
] 96 [4.60]
99 [4.74]
100 [4.79]
106 [5.08]
137 [6.56]
147 [7.04]
Table 19