Floor Load Data
Specification
20
30
40
60
80
100
Dynamic floor load, lbs. [kN]
420 [1.86]
630 [2.80]
840 [3.74]
1260 [5.61]
1680 [7.48]
1680 [7.48]
Dynamic floor pressure, lbs.-
ft2 [kN-m
2
]
96 [4.60]
109 [5.22]
119 [5.70]
143 [6.85]
149 [7.13]
149 [7.13]
Dynamic load
frequency, Hz
F-speed
9.7
9.0
8.6
8.1
7.4
7.4
V-speed
13.7
12.8
12.2
11.4
10.4
9.5
Maximum moment about ma-
chine base, lbs.-ft. [kN-m]
805 [1.09]
1260 [1.71]
1820 [2.47]
2770 [3.76]
4330 [5.87]
4330 [5.87]
Maximum vertical load, lbs.
[kN]
795 [3.54]
1150 [5.12]
1470 [6.54]
2080 [9.25]
3050 [13.57]
3140 [13.82]
N/A = Not Applicable
Table 19
Drain Connection
IMPORTANT: Machine must be installed in accordance
with all local codes and ordinances.
All drain systems must be vented to prevent an air lock or siphon-
ing.
Use the supplied black rubber adapter and clamps to transition
from the machine drain outlet to the 2 inches [51 mm] schedule
40 PVC plumbing (20 and 30 models) and the 3 inches [76
mm]schedule 40 PVC plumbing (40-100 models).
If proper drain size is not available or practical, a surge tank is
required. A surge tank along with a sump pump should be used
when gravity drainage is not possible.
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
44
Part No. F8429301ENR15
Содержание SCB040GNF
Страница 2: ......