Rockwell Automation Publication 520-UM002B-EN-E - December 2017
95
PowerFlex 527 Integrated Safe Torque-Off
Chapter 4
Propose TUNID Blocked
The attribute Propose TUNID Blocked can be used to check if the drive is in a
state where it will accept a safety connection. If the drive is enabled, it will not
accept a safety connection.
Safe Torque-Off Mode
The attribute STO Mode can be used to check if the PowerFlex 527 is in STO
Bypass Mode.
Safe Torque-Off Faults
When a safety fault is indicated in any of the following tags:
•
SI.SafetyFault
•
Axis.SafetyFaultStatus
•
Axis.SafetyTorqueOffFault
Propose TUNID Blocked: MSG
Parameter
Value
Description
Service Code
0x0E
Get Attribute Single
Class
0x5A
Safety Stop Functions
Instance
0
Class attribute
Attribute
0x65
STO Mode
Data Type
SINT
Unsigned Short Integer
Safe Torque-Off Mode: Values
Value
Definition
0
Accept a safety connection
1
Block a safety connection
Safe Torque-Off Mode: MSG
Parameter
Value
Description
Service Code
0x0E
Get Attribute Single
Class
0x5A
Safety Stop Functions
Instance
1
Axis number
Attribute
0x104
STO Mode
Data Type
SINT
Unsigned Short Integer
Safe Torque-Off Mode: Values
Value
Definition
1
Normal Operation
2
STO Bypass Mode
Содержание PowerFlex 527
Страница 1: ...PowerFlex 527 Adjustable Frequency AC Drive Catalog Number 25C User Manual Original Instructions...
Страница 4: ...4 Rockwell Automation Publication520 UM002B EN E December 2017 Summary of Changes Notes...
Страница 8: ...8 Rockwell Automation Publication 520 UM002B EN E December 2017 Table of Contents Notes...
Страница 102: ...102 Rockwell Automation Publication520 UM002B EN E December 2017 Chapter 5 Hardwired Control of Safe Torque Off Notes...
Страница 162: ...162 Rockwell Automation Publication520 UM002B EN E December 2017 Appendix B Accessories and Dimensions Notes...
Страница 173: ...Rockwell Automation Publication520 UM002B EN E December 2017 173 Notes...
Страница 174: ...174 Rockwell Automation Publication 520 UM002B EN E December 2017 Notes...
Страница 175: ......