Chapter 2
Information Display
From the axis state screen, press Select
or the Down
arrow to access
the following information menu:
Network Configuration
Through the settings option, you can configure the drive IP address. There are
two methods for configuring the drive IP address:
• Static IP
– Use Static IP when you want to manually configure the IP
address, subnet mask, and gateway addresses.
• DHCP
(
Dynamic Host Configuration Protocol
) – Use DHCP when
you want convenience and ease-of-use compared to Static IP. The IP
address, subnet mask, and gateway addresses will be assigned automatically
by the DHCP server.
Screen Option
Description
Example Display
(1)
(1) The LCD only accommodates up to five characters. Text strings that are more than five characters are scrolled.
Version Info
Provides information on the hardware and software
versions.
HW Ver 01.002 FW Ver 01.102
Device Info
Provides information on the drive type, network
configuration, and IP address.
PowerFlex 527 Static IP 192.168.1.180
or
PowerFlex 527 DHCP 192.168.1.180
(2)
(2) If “0.0.0.0” is displayed and DHCP is enabled, it means that the IP address has not been assigned by the DHCP server. Check your
network settings.
Settings
Allows configuration of network settings, changing the
display language, and resetting the drive.
See
Network Configuration on page 47
for instructions on how to configure
the IP address.
IMPORTANT
Regardless of the method used to set the adapter IP address, each node on the
EtherNet/IP network must have a unique IP address. To change an IP address,
you must set the new value and then power cycle the drive.
You can also use the Reset function, however all safety connections will have to
be disabled before this option is available.
You must enter a valid IP address configuration. With firmware 1.008 or later, if
an illegal IP address configuration exists upon power up, for example, if the IP
address and gateway address are identical, the drive faults and exhibits INIT
FLT M22 - ILLEGAL ADDRESS on the display and the IP address configuration
changes to DHCP.
Sel
Содержание PowerFlex 527
Страница 1: ...PowerFlex 527 Adjustable Frequency AC Drive Catalog Number 25C User Manual Original Instructions...
Страница 4: ...4 Rockwell Automation Publication520 UM002B EN E December 2017 Summary of Changes Notes...
Страница 8: ...8 Rockwell Automation Publication 520 UM002B EN E December 2017 Table of Contents Notes...
Страница 102: ...102 Rockwell Automation Publication520 UM002B EN E December 2017 Chapter 5 Hardwired Control of Safe Torque Off Notes...
Страница 162: ...162 Rockwell Automation Publication520 UM002B EN E December 2017 Appendix B Accessories and Dimensions Notes...
Страница 173: ...Rockwell Automation Publication520 UM002B EN E December 2017 173 Notes...
Страница 174: ...174 Rockwell Automation Publication 520 UM002B EN E December 2017 Notes...
Страница 175: ......