Rockwell Automation Publication 520-UM002B-EN-E - December 2017
135
Supplemental Drive Information
Appendix A
Technical Specifications
Protection
Electrical
Control
Specifications
PowerFlex 527
Bus Overvoltage Trip
100...120V AC Input:
200...240V AC Input:
380...480V AC Input:
525...600V AC Input:
405V DC bus (equivalent to 150V AC incoming line)
405V DC bus (equivalent to 290V AC incoming line)
810V DC bus (equivalent to 575V AC incoming line)
1005V DC bus (equivalent to 711V AC incoming line)
Bus Undervoltage Trip
100...120V AC Input:
200...240V AC Input:
380...480V AC Input:
525...600V AC Input
190V DC bus (equivalent to 75V AC incoming line)
190V DC bus (equivalent to 150V AC incoming line)
390V DC bus (equivalent to 275V AC incoming line)
487V DC bus (equivalent to 344V AC incoming line)
Power Ride-Thru:
100 ms
Logic Control Ride-Thru:
0.5 s minimum, 2 s typical
Electronic Motor Overload
Protection:
Provides class 10 motor overload protection according to NEC article 430 and motor
over-temperature protection according to NEC article 430.126 (A) (2).
UL 508C File 29572.
Overcurrent:
200% hardware limit, 300% instantaneous fault
Ground Fault Trip:
Phase-to-ground on drive output
Short Circuit Trip:
Phase-to-phase on drive output
Specifications
PowerFlex 527
Voltage Tolerance:
-15% / +10%
Frequency Tolerance:
47...63 Hz
Input Phases:
Three-phase input provides full rating. Single-phase input provides 35% rating on
three-phase drives.
Displacement Power Factor:
0.98 across entire speed range
Maximum Short Circuit Rating:
100,000 Amps Symmetrical
Actual Short Circuit Rating:
Determined by AIC Rating of installed fuse/circuit breaker
Transistor Type:
Isolated Gate Bipolar Transistor (IGBT)
Internal DC Bus Choke
200...240V AC Input:
380...480V AC Input:
525...600V AC Input:
Only for Frame E drive ratings
11 kW (15 HP)
15...18.5 kW (20...25 HP) – Heavy Duty
15...18.5 kW (20...25 HP) – Heavy Duty
Specifications
PowerFlex 527
Method
•
Frequency Control:
–
Basic Volts/Hertz
–
Fan/Pump Volts/Hertz
–
Sensorless Vector Control (SVC)
–
Sensorless Vector Control (SVC) Economizer
•
Position Loop:
–
Closed Loop Position Vector Control (with optional encoder card)
•
Velocity Loop:
–
Closed Loop Velocity Vector Control (with optional encoder card)
Carrier Frequency
2...8 kHz, Drive rating based on 4 kHz
Frequency Accuracy
Within ±0.05% of set output frequency
Performance
V/Hz (Volts per Hertz):
SVC (Sensorless Vector):
SVC Economizer:
±1% of base speed across a 60:1 speed range
±0.5% of base speed across a 100:1 speed range
±0.5% of base speed across a 100:1 speed range
Содержание PowerFlex 527
Страница 1: ...PowerFlex 527 Adjustable Frequency AC Drive Catalog Number 25C User Manual Original Instructions...
Страница 4: ...4 Rockwell Automation Publication520 UM002B EN E December 2017 Summary of Changes Notes...
Страница 8: ...8 Rockwell Automation Publication 520 UM002B EN E December 2017 Table of Contents Notes...
Страница 102: ...102 Rockwell Automation Publication520 UM002B EN E December 2017 Chapter 5 Hardwired Control of Safe Torque Off Notes...
Страница 162: ...162 Rockwell Automation Publication520 UM002B EN E December 2017 Appendix B Accessories and Dimensions Notes...
Страница 173: ...Rockwell Automation Publication520 UM002B EN E December 2017 173 Notes...
Страница 174: ...174 Rockwell Automation Publication 520 UM002B EN E December 2017 Notes...
Страница 175: ......