Rockwell Automation Publication 520-UM002B-EN-E - December 2017
61
Configuring the PowerFlex 527 Drive with Integrated Motion
Chapter 3
Configure Drive with Integrated Safety Connections
Follow these steps to configure PowerFlex 527 drives with integrated safety.
1.
Ensure that you have done the steps in
before proceeding.
2.
Under Module Definition, click Change.
The Module Definition dialog box appears.
a. From the Electronic Keying pull-down menu, choose an option.
b. From the Connection pull-down menu, choose the Connection mode
for your motion application.
In this example, choose Motion and Safety.
The Safety Network Number (SNN) field populates automatically when
the Connection mode includes an integrated Motion and Safety or Safety-
only connection. For a detailed explanation of the safety network number,
see the GuardLogix Controller Systems Safety Reference Manual,
publication
WARNING:
When using motion modules, the electronic keying must
be either “Exact Match” or “Compatible Keying”.
Never use “Disable Keying” with motion modules.
TIP
When ‘Safety’ appears in the Connection mode, integrated safety is
implied.
Содержание PowerFlex 527
Страница 1: ...PowerFlex 527 Adjustable Frequency AC Drive Catalog Number 25C User Manual Original Instructions...
Страница 4: ...4 Rockwell Automation Publication520 UM002B EN E December 2017 Summary of Changes Notes...
Страница 8: ...8 Rockwell Automation Publication 520 UM002B EN E December 2017 Table of Contents Notes...
Страница 102: ...102 Rockwell Automation Publication520 UM002B EN E December 2017 Chapter 5 Hardwired Control of Safe Torque Off Notes...
Страница 162: ...162 Rockwell Automation Publication520 UM002B EN E December 2017 Appendix B Accessories and Dimensions Notes...
Страница 173: ...Rockwell Automation Publication520 UM002B EN E December 2017 173 Notes...
Страница 174: ...174 Rockwell Automation Publication 520 UM002B EN E December 2017 Notes...
Страница 175: ......