Publication 1766-RM001A-EN-P - October 2008
506
Socket Interface Using CIP Generic Messaging
MSG Configuration Parameters
To call this service, click "Setup Screen" in the MSG instruction and enter
the values displayed below.
Configure the MSG with these values:
CIP Generic Msg Parameter
Description
Channel
1 (Integral)
Communication Command
CIP Generic
Service
Custom
Service Code
4F (hexadecimal)
Class
342 (hexadecimal)
Instance
0 Use a relay ladder instruction to move the returned
instance number from a CreateSocket service into the
MGx:y.TFN element of a MSG instruction.
Attribute
0
Data Table Address (Send)
Not used.
Size in Bytes (Send)
0 bytes
Data Table Address (Receive)
Not used.
Size in Bytes (Receive)
0 bytes
Extended Routing Info File(RIX)
Specify RIX file
To Address in MultiHop tab
127.0.0.1
Considerations :
Delete a socket instance if it is no longer needed. If unused instances are not deleted and you
continue to create additional instances, you can exceed the maximum number of instances.
efesotomasyon.com - Allen Bradley,Rockwell,plc,servo,drive