Rockwell Automation Publication 23PFC-TG001A-EN-P - March 2018
117
Frame B Field Controller Part Replacement Procedures
Chapter 4
Cooling Fan Replacement
Remove the Cooling Fans
1. Read the General Safety Precautions on page
2. Remove power from the device (see page
3. Remove the two screws that secure the rear plastic shield to the bottom
of the device and remove the shield.
4. Locate the cooling fan terminal block on the bottom of the device and
loosen the screws that secure the fan power supply wires (red and black)
to the terminal block and remove the wires.
IMPORTANT
Note the color and location of each of the wires that are connected
to the cooling fan to ensure that each wire is properly connected
during installation.
3
Bottom View