B 140
Alcatel Vacuum Technology France - ATP User’s Manual
Functions of integrable controller
OEM Board type
2/3
GB 00422 - Edition 02 - March 00
Depending on P2 power supply cable connector wiring,
the pump Start/Stop and an external safety can be remote
controlled.
J3 connector allows the copy of
the pump status data (equivalent
to light indicators green-red-
yellow) (
voir folio 1
).
Remote control mode
J2
+12V
0V
0V
240V
Terre
220V
200V
115V
100V
+5V
1
2
J3
Pump
cable
Description
Standard wiring.
A4-A5
: output by contact
ON/OFF
Without remote control
outer safeties
Buttons command.
The buttons of the front of
panel are operational.
Pump Start/Stop
remote control
(by impulse contacts)
Interrupter command.
Closed contact:
pump starts
Opened contact:
pump stops
Pump Start/Stop
remote control
(by maintained contact)
Opened contact:
pump stops
No indication by the red
LED.
Outer safety switch wiring
A4-A5
terminals allows to
switch 250 V - 1 A max.
Outer control
P2 connector wiring*
1
B
A
3
2
4
5
1
B
A
3
2
4
5
START
STOP
1
B
A
3
2
4
5
1
B
A
3
2
4
5
1
B
A
3
2
4
5
250 V 1 A max.
* P2 soldering side view;
B2 and A1 in black are female pins, others are male pins.