9/10
B 120
Alcatel Vacuum Technology France - ATP User’s Manual
Detailed description of RS commands
GB 00420 - Edition 03 - March 00
SET
Syntax
Result
See also:
LEV
SHT
Syntax
Result
See also:
LNG
SPD
Syntax
Result
See also:
LNG
,
SHT
Defines the internal operating parameters
#adr
SET
1 hhhhh<CR>[<LF>]
maintenance time
#adr
SET
2 sssss<CR>[<LF>]
maximum time for start-up
(future)
Complete cabinet only:
#adr
SET
10 ccccc<CR>[<LF>] :
pump working time
(in hours)
#adr
SET
11 eeeee<CR>[<LF>] :
electronic working time
(in hours)
#adr
SET
12 g<CR>[<LF>] :
regreasing counter
(0 to 2 max)
#adr
SET
13 ddddd<CR>[<LF>] :
start delay (max 14459s,
that is 240mn 59s)
#adr
SET
14 pppp<CR>[<LF>] :
time to venting (max 3599s,
that is 59mn 59s)
#adr
SET
15 qqqq<CR>[<LF>] :
venting time (max 3599s,
that is 59mn 59s)
#adr,ok
or
#adr,ErrX
Returns the transmitted string without the identification
sub-string
#adr
SHT
<CR>[<LF>]
#adr,ok
The strings sent following
DLR
,
LEV
and
SPD
commands will now be
sent without the parameter identification
sub-strings (e.g; without the units).
Returns the current speed
#adr
SPD
<CR>[<LF>]
#adr,nnnnn
#adr,nnnnn rpm