![Alcatel Vacuum Technology Adixen ATP 100 Скачать руководство пользователя страница 102](http://html.mh-extra.com/html/alcatel-vacuum-technology/adixen-atp-100/adixen-atp-100_user-manual_2891737102.webp)
E 70
Pump running-in for
ATP 80, ATP 100, ATP 150, ATP 400
Alcatel Vacuum Technology France - ATP User’s Manual
1/3
GB 00443 - Edition 02 - February 99
Running-in after ball
bearing replacement
Running-in after pump
lubrication
Running-in program No. 1
duration
≈
20 hours
This operation is used to obtain the pump's initial
performance in terms of reliability, noise level, vibration
and power consumption.
Running-in program No. 2
duration
≈
2 h 30
This operation is used to fine-tune the distribution of
the grease in the bearings.
It consists of pump operation cycles at different speeds to
distribute gradually and regularly the grease through
the ball bearings.
The pump must undergo a
running-in operation
The running-in consist to run Start/Stop cycles at different
speeds until a pre-defined rotational speed is reached.
A phase is made of a chain of identical cycles.
During the running-in, cycle and phase counters are
decremented to display
The running-in is ended.
Pre-defined
rotation
speed
Test at pre-defined
rotation speed reached
t
0
START
STOP
PROG:1
END
PH:0
CYCLE:0
Cycle diagram