1
2
3
4
5
6
A
B
C
D
6
5
4
3
2
1
D
C
B
A
Title
Number
Revision
Size
B
Date:
13-Mar-2015
Sheet of
File:
L:\Check\Jeff\schematics-copies\0027.00.900-K.ddb
Drawn By:
Joe Koutrakos
AIR-VAC Engineering Inc
30 Progress Ave, Seymour CT. 06483
WWW.air-vac-eng.com
1
Elect, Schem, DRS27 AC Power Distribution
0027.00.900
220V AC (L3)
220V AC (L2)
CHS GND
220V AC (L1)
F8
3A
F9
.5a slow blow
+24ret AC cont
A2
A1
1
2
4
6
3
5
8
7
14
13
22
21
contactor
LC1DT25-BL
F10
.5a slow blow
F10
.5a slow blow
F9
.5a slow blow
F8
3A
F7
4A
F7
4A
B 1
Breaker, 3 Pole
25A / 35 A
+24VDC Estop
sw2b
SW-PB
sw2a
SW-PB
Start Switch
sw1
SW-PB N/C
Estop
Start Switch
SW2c
SW-PB N/C
A2
A1
1
2
4
6
3
5
8
7
14
13
22
21
contactor
LC1DT25-BL
4 A
B2
Breaker, 2 Pole
1
2
3
4
5
AC
CON5
1
2
3
4
5
6
AC
CON6
1
2
3
4
5
6
7
AC
CON7
L AC HOT
G GND
24Vdc +
24Vdc +
24Vdc +
24Vdc +
24Vdc +
24Vdc +
24V RET -
24V RET -
24V RET -
24V RET -
24V RET -
24V RET -
24V RET -
GND G
AC HOT L
+5Vdc V2
AC NEUTRAL N
NC NC
24/5 RET COM
24/5 RET COM
+24Vdc V1
PS 2
(-15Vdc) -V
L AC HOT
PS3
CTRL
N AC NEUTRAL
+/- 15VDC
COM
COM
N/C
G GND
(+15Vdc) +V
+5V Spare
+5V
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
J2
+5/24 vdc RET
Earth Ground
24 V ret
5/24 VPS RET
+24V
M 1 +24 VDC
M 2 +24 VDC
+15V
15V COM
-15V
+24V
M 3 +24V RET
M 4 +24V RET
Temp Ctrl L
Temp Ctrl N
24V RET CON
TB 4
TB 5
POWER
LED
TB 6
F6
12A
F6
12A
F5
12A
F5
12A
F4
12A
F4
12A
F3
10A
F3
10A
CPU NUE
CPU HOT
1
2
3
J3
AC POWER PANEL
POWER SUPPLY PANEL
N AC NEUTRAL
114
103
105
117
113
+24VDC Estop
+24ret AC cont
62
11
21
13
260
60
176
61
59
55
54
58
52
115
53
116
105
104
116
53
115
52
13
21
11
98
84
90
96
89
83
97
85
17 / 62
83
98
97
85
179
178
177
84
98
97
85
83
96
179
178
177
179
178
177
177 / 17
178
179
96
83
85
97
98
84
207
208
207 / 209
208 / 210
209 / 211
212
78 / 213
82 / 219
1
2
1
2
104
105
84
89
90
96
89
90
60 / 260
61 / 176
55 / 59
54 / 58
17
17
1
2
3
4
5
6
7
8
9
10
11
12
13
14
AC
CON14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
AC
CON14
105
104
199
215
198
95
197
94
196
93
72 / 92
87
92
86 / 87
99
88
218
216
172
173
174
175
77
76
78
82
73 / 77
74
75 / 76
Temp Cont
Temp Cont
24v Motor
24v Motor
15v PS
15v PS
24 / 5 PS
24 / 5 PS
194
193
100
101
102
218 / 72
99 / 86
216 / 88
219
212 / 210
213 / 211
194
193
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
J2
62
11
21
13
260
60
176
307
55
54
306
52
115
53
116
1B6
1B6
9C4
1D2
2A1
2A1
3D5
3D5
6C2
7C1
7C1
7C1
7B1
9C3
7B1
8B1
9C3
9C3
8B1
9B3
9B3
9B3
9B3
1D1
1D1
A2 AC CONT 3
386
385
10D1
MONITOR HOT
MONITOR NUE
170
169
2A1
2A1
Motor PS
PS 1
AC Power (L3)
AC Power (L2)
AC Power (L1)
10C1
10C1
10C1
193
TB3
L2 220V Spot Htr
L1 220V Spot Htr
L3 220V Spot Htr
110
111
112
10C1
10C1
10C1
N 220V Spot Htr
428
10C1
427 / 428
N
UH220V HOT
UH220V RET
Bottom Front HOT
Bottom Front RET
Bottom Back HOT
Bottom center RET
Bottom Center HOT
Bottom Back RET
DOUT 0 AC CONT 2
6C3
2B1
2B1
2B1
2C1
2C1
2D1
2D1
2D1
A1 AC CONT 3
10D1
427
AC Power (N)
10C1
429
4 Wire Configuration (USA)
114
TB2
103
TB1
TB10 90 / 89
* NOTE: B1 will be 35A with Spot Heater Option
170 / 173
169 / 172
104
K
16
Содержание DRS27
Страница 1: ...DRS27 ...
Страница 2: ......
Страница 4: ......
Страница 6: ...DRS27 User s Manual Table of Contents 0027 00 902 ...
Страница 8: ...DRS27 User s Guide Chapter 1 Introduction Overview 0027 00 902 1 2 ...
Страница 26: ...DRS27 User s Guide Chapter 1 Introduction Overview 0027 00 902 1 20 ...
Страница 28: ...DRS27 User s Guide Chapter 2 Requirements and Installation 0027 00 902 2 2 ...
Страница 64: ...DRS27 User s Guide Chapter 3 Machine Function Verifications 0027 00 902 3 2 ...
Страница 88: ...DRS27 User s Guide Chapter 4 Software Overview 0025 00 902 4 2 ...
Страница 107: ...DRS27 User s Guide Chapter 4 Software Overview 0025 00 902 4 21 4 2 Control Menu Functions View of the Control Menu ...
Страница 178: ...DRS27 User s Guide Chapter 5 Process Development Guide Engineering Training 0027 00 902 5 2 ...
Страница 181: ...DRS27 User s Guide Chapter 5 Process Development Guide Engineering Training 0027 00 902 5 5 Thermocouple Ports ...
Страница 215: ...DRS27 User s Guide Chapter 5 Process Development Guide Engineering Training 0027 00 902 5 39 ...
Страница 222: ...DRS27 User s Guide Chapter 6 Templates Removal Site Clean Replacement 0027 00 902 6 2 ...
Страница 255: ...DRS27 User s Guide Chapter 6 Templates Removal Site Clean Replacement 0027 00 902 6 35 Nozzle cool down Board cool down ...
Страница 258: ...DRS27 User s Guide Chapter 7 Operator Training 0027 00 902 7 2 ...
Страница 302: ...DRS27 User s Guide Chapter 8 Maintenance 0027 00 902 8 2 ...
Страница 309: ...DRS27 User s Guide Chapter 8 Maintenance 0027 00 902 8 9 8 4 Assembly Diagrams ...
Страница 310: ...DRS27 User s Guide Chapter 8 Maintenance 0027 00 902 8 10 ...
Страница 328: ......
Страница 330: ...DRS27 User s Guide Chapter 9 Schematics 0027 00 902 9 2 ...
Страница 332: ......
Страница 334: ......
Страница 336: ......
Страница 338: ......
Страница 340: ......
Страница 342: ......
Страница 344: ......
Страница 346: ......
Страница 348: ......
Страница 350: ......
Страница 352: ......
Страница 354: ......
Страница 356: ......
Страница 358: ......
Страница 360: ......
Страница 362: ......
Страница 364: ......
Страница 366: ......
Страница 368: ......
Страница 370: ......
Страница 372: ......
Страница 374: ......
Страница 376: ......
Страница 378: ......
Страница 380: ......
Страница 382: ......
Страница 384: ......