6
4 – INSTALLATION
SECTION 4 – INSTALLATION
4.1 – RECEIVING AND INSPECTION
• Carefully remove the VELTRON DPT-
plus
from the shipping container and inspect for any damage. If any damage has
occurred in transit, contact freight carrier.
• Save the shipping container for possible future use in returning the VELTRON DPT-
plus
to the factory for recalibration.
• Included in the shipping container are two spare fuses and Mounting Bracket Kit consisting of: Two-piece bracket, U-
bolt, and necessary hardware. If any items are missing, contact the Customer Service Department at 1-800-AIR-
FLOW.
• Review the Factory Set-Up Information Sheet provided separately and verify the W.O. # and Serial # match those on
the VELTRON DPT-
plus
. Verify that the configuration recorded on the Factory Set-Up Information Sheet is correct for
your application. If not, contact Air Monitor's Customer Service Department at 1-800-AIRFLOW for further guidance.
Note:
The VELTRON DPT
-
plus
has been configured and calibrated to customer specified parameters (see "Fac-
tory Setup Information Sheet" at the end of this Manual), and requires no additional calibration/verification
prior to installation.
4.2 – LOCATION
• The VELTRON DPT-
plus
is housed in a NEMA Type 4X enclosure which is suitable for outdoor locations.
• The VELTRON DPT-
plus
is Factory Mutual approved as explosion proof for Class I, Division 1, Group B, C, and D;
dust-ignition proof for Class II/III, Division 1, Groups E, F, and G hazardous (classified) location, indoor and outdoor
(NEMA Type 4X).
• The ambient temperature of the selected mounting location must be between 32º – 140ºF. Consideration should be
given to units installed in enclosures exposed to direct sunlight.
• The VELTRON DPT-
plus
may be mounted in any position or attitude and is not affected by any reasonable shock or
vibration.