![Air Lift LoadLifter 7500 XL Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/air-lift/loadlifter-7500-xl/loadlifter-7500-xl_installation-manual_2874965025.webp)
MN-1033
23
E. Installing the Air Lines
INSTALLING THE HEAT SHIELD
1 . Attach the metal heat shield to the exhaust where it is closest to the air spring . Slide
the air line thermal sleeve over the air line and place it where the air line is closest to
the exhaust . (Fig . E .4) .
Hex nuts
Star washer
Rubber washer
Air Line Setup for Compressor Integration
Air Line Setup Without Compressor System
Vehicle body
or bumper
Hex nuts
Flat washer
Star washer
Rubber washer
Nylon air line
to compressor
system and
Schrader valve
Flat
Flat
Vehicle body
or bumper
Braided stainless steel
air line to air spring
5/16” (8mm)
hole
AN to PTC
fitting
Schrader
valve
Vehicle
body or
bumper
AN
Schrader
valve
Air line hex nut
Flat washer
Nylon air line
to air spring
5/16” (8mm) hole
Braided
stainless
steel air line
to air spring
Hex nuts
Flat washer
Star washer
Rubber washer
Schrader
valve
Vehicle
body or
bumper
Nylon air line
to air spring
5/16” (8mm) hole
Choose the locations for
the Schrader valves and
drill a 5/16" (8mm) hole, if
necessary (Fig . E .1) .
1 . Cut the air line in half .
Make clean, square cuts
with a razor blade or
hose cutter (Fig . E .2) . Do
not use scissors or wire
cutters .
KEEP AT LEAST 6” (152MM)
OF CLEARANCE BETWEEN
ALL AIR LINES AND THE
EXHAUST SYSTEM . AVOID
SHARP BENDS AND EDGES .
2 . Use zip ties to secure
the air line to fixed points
along the chassis . Do not
pinch or kink the air line .
Leave at least 2” (51mm)
of slack in the air line to
allow for any movement
that might pull on the air
line . The minimum bend
radius for the air line is 1"
(25mm) .
3 . Install the Schrader valve
in the chosen location
(Fig . E .3) .
fig. E.2
fig. E.1
A. Inside fuel tank filler door
C. License plate or
B. Inside rear wheel wells
rear bumper area
MICHIGAN
XXX-XXX
www.MICHIGAN.gov
A.
B.
C.
MICHIGAN
XXX-XXX
www.MICHIGAN.gov
If a location for the Schrader valve other than the back of
the vehicle is chosen, it may be necessary to coil the
excess air line. The braided stainless steel air line cannot
be trimmed.
A. Inside fuel
tank filler
door
B. Inside rear
wheel wells
C. License
plate or rear
bumper area*
* For LoadLifter 5000 Ultimate Plus kits, the recommended location
for the Schrader valves is the rear bumper area or license plate.
MICHIGAN
XXX-XXX
www.MICHIGAN.gov
A.
B.
C.
USE IN
Standard,
Ultimate,
7500XL
USE IN
Plus
upgrade kit
USE IN
Plus combo
manuals
MICHIGAN
XXX-XXX
www.MICHIGAN.gov
If a location for the Schrader valve other than the back of the vehicle is
chosen, it may be necessary to coil the excess air line. The braided
stainless steel air line cannot be trimmed.
USE IN
Plus
upgrade kit
fig. E.3
Good cut
Bad cut
fig. E.4
Air line
thermal sleeve
Exhaust
resonator
Bend
tabs
Double hose
clamps if
necessary
1/2” (13mm)
dead air space
between shield
and exhaust
LoadLifter 7500
XL
23
CAUTION
Содержание LoadLifter 7500 XL
Страница 2: ......